TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump
/ Page 17
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA060H4
5 TON
Up−Flow Indoor Coils
Up−Flow Coils
57,000
54,500
35,800 13.00 11.00 7.70 6.70 5180 4955 4415 3.22 2.38
3
CX34−62D−6F
Factory TXV
58,500
55,000
36,000 13.00 11.00 7.70 6.70 5320 4850 4325 3.32 2.44
3
CX34−62C−6F
Factory TXV
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
57,500
54,000
35,200 14.00 11.50 8.20 7.20 5000 4820 4270 3.28 2.42 CX34−62D−6F
4
G61MPV−60D−135
Factory TXV
57,500
54,000
35,200 14.00 11.50 8.20 7.20 5000 4820 4270 3.28 2.42 CX34−62D−6F
4
G71MPP−60D−135 Factory TXV
58,000
54,500
35,800 14.00 11.50 8.20 7.50 5045 4835 4295 3.30 2.44 CX34−62C−6F
4
G61MPV−60C−090
Factory TXV
58,000
54,500
35,800 14.00 11.50 8.20 7.50 5045 4835 4295 3.30 2.44 CX34−62C−6F
4
G71MPP−60C−090 Factory TXV
58,000
55,000
36,000 14.00 11.50 8.20 7.20 5045 4885 4355 3.30 2.42 CX34−62C−6F
4
G61MPV−60C−091
Factory TXV
58,500
54,500
35,400 14.50 12.00 8.20 7.20 4875 4725 4240 3.38 2.44 CX34−62D−6F
4
G60UHV−60D−135
Factory TXV
58,500
54,500
35,600 14.00 11.50 8.20 7.50 5085 4750 4220 3.36 2.48 CX34−62C−6F
4
G60UHV−60C−090
Factory TXV
58,500
54,500
35,600 14.00 11.50 8.20 7.50 5085 4765 4235 3.36 2.46 CX34−62C−6F
4
G60UHV−60C−110
Factory TXV
58,500
54,500
35,800 14.00 11.50 8.20 7.50 5085 4800 4270 3.32 2.46 CX34−62C−6F
4
G61MPV−60C−110
Factory TXV
58,500
54,500
35,800 14.00 11.50 8.20 7.50 5085 4800 4270 3.32 2.46 CX34−62C−6F
4
G71MPP−60C−110
Factory TXV
58,500
55,000
35,800 14.00 11.50 8.20 7.50 5085 4815 4290 3.34 2.44 CX34−62C−6F
4
G61MPV−60C−111
Factory TXV
Horizontal Indoor Coils
Horizontal Coils
56,500
54,500
35,600 13.00 11.00 7.70 6.70 5135 5005 4465 3.20 2.34
3
CH33−62D−2F
2
91M02
57,000
54,500
35,800 13.00 11.00 7.70 6.70 5180 4965 4405 3.22 2.38
3
CH33−50/60C−2F
2
91M02
57,500
55,500
36,200 13.00 11.00 7.70 6.70 5225 4615 4180 3.52 2.54
3
CH23−68
2
91M02
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
56,500
54,500
35,800 13.50 11.00 8.20 7.20 5135 4985 4405 3.20 2.38 CH33−50/60C−2F
4
G61MPV−60C−090
2
91M02
56,500
54,500
35,800 13.50 11.00 8.20 7.20 5135 4985 4405 3.20 2.38 CH33−50/60C−2F
4
G71MPP−60C−090
2
91M02
57,000
54,500
35,600 14.00 11.50 8.20 7.20 4955 4900 4340 3.26 2.40 CH33−50/60C−2F
4
G60UHV−60C−090
2
91M02
57,000
54,500
35,600 14.00 11.50 8.20 7.20 4955 4920 4350 3.24 2.40 CH33−50/60C−2F
4
G60UHV−60C−110
2
91M02
57,000
54,500
35,800 13.50 11.00 8.20 7.20 5180 4950 4385 3.22 2.40 CH33−50/60C−2F
4
G61MPV−60C−110
2
91M02
57,000
54,500
35,800 13.50 11.00 8.20 7.20 5180 4950 4385 3.22 2.40 CH33−50/60C−2F
4
G71MPP−60C−110
2
91M02
57,000
54,500
35,800 13.50 11.00 8.20 7.20 5180 4960 4400 3.22 2.38 CH33−50/60C−2F
4
G61MPV−60C−111
2
91M02
57,500
54,500
35,800 14.00 11.50 8.20 7.20 5000 4875 4375 3.28 2.40 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
57,500
54,500
35,800 14.00 11.50 8.20 7.20 5000 4875 4375 3.28 2.40 CH33−62D−2F
4
G71MPP−60D−135
2
91M02
57,000
54,500
36,000 13.50 11.00 8.20 7.20 5180 5030 4465 3.18 2.36 CH33−50/60C−2F
4
G61MPV−60C−091
2
91M02
57,500
55,500
35,800 14.00 11.50 8.20 7.50 5000 4560 4115 3.56 2.54 CH23−68
4
G61MPV−60C−090
2
91M02
57,500
55,500
35,800 14.00 11.50 8.20 7.50 5000 4560 4115 3.56 2.54 CH23−68
4
G71MPP−60C−090
2
91M02
57,500
55,500
35,800 14.00 11.50 8.20 7.50 5000 4535 4100 3.58 2.56 CH23−68
4
G61MPV−60C−110
2
91M02
57,500
55,500
35,800 14.00 11.50 8.20 7.50 5000 4535 4100 3.58 2.56 CH23−68
4
G71MPP−60C−110
2
91M02
57,500
55,500
36,000 14.00 11.50 8.20 7.50 5000 4620 4185 3.52 2.52 CH23−68
4
G61MPV−60C−091
2
91M02
57,500
55,500
36,000 14.00 11.50 8.20 7.50 5000 4550 4115 3.58 2.56 CH23−68
4
G61MPV−60C−111
2
91M02
58,000
54,000
35,400 14.00 12.00 8.20 7.20 4835 4760 4265 3.32 2.44 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
58,000
55,000
35,600 14.00 11.50 8.20 7.70 5045 4475 4045 3.60 2.58 CH23−68
4
G60UHV−60C−090
2
91M02
58,000
55,000
35,600 14.00 12.00 8.20 7.50 4835 4475 4040 3.60 2.58 CH23−68
4
G61MPV−60D−135
2
91M02
58,000
55,000
35,600 14.00 12.00 8.20 7.50 4835 4475 4040 3.60 2.58 CH23−68
4
G71MPP−60D−135
2
91M02
58,500
55,500
35,800 14.50 12.00 8.20 7.50 4875 4405 3995 3.70 2.62 CH23−68
4
G60UHV−60D−135
2
91M02
58,500
56,000
36,200 14.00 11.50 8.20 7.50 5085 4525 4130 3.62 2.56 CH23−68
4
G60UHV−60C−110
2
91M02
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.