TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump
/ Page 12
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA042H4
3.5 TON
Air Handlers
Air Handlers
42,500
45,000
27,800 14.00 12.00 8.00 7.20 3540 3890 3540 3.40 2.30
4
CBX32M−048 (Multi−Position)
2
49L25
42,500
45,500
28,200 14.00 12.00 8.20 7.20 3540 3650 3320 3.66 2.48
5
CBX26UH−042 (Up−Flow / Horizontal)
Factory TXV
43,500
44,500
27,400 15.00 12.50 8.20 7.20 3480 3735 3405 3.50 2.36
4
CBX27UH−042 (Up−Flow / Horizontal)
Factory TXV
43,500
44,500
27,600 14.50 12.50 8.20 7.20 3480 3785 3465 3.44 2.34
4
CBX32MV−048 (Multi−Position)
2
49L25
Up−Flow Indoor Coils
Up−Flow Coils
41,500
42,000
27,000 13.00 11.00 7.70 6.70 3775 3440 3145 3.58 2.52
3
CX34−60D−6F
2
49L25
42,000
42,000
26,800 13.00 11.00 7.70 6.70 3820 3475 3165 3.54 2.48
3
CX34−49C−6F
2
49L25
42,000
42,000
27,000 13.00 11.00 7.70 6.70 3820 3435 3120 3.58 2.54
3
CX34−62D−6F
2
49L25
42,500
42,500
27,200 13.00 11.00 7.70 6.70 3865 3350 3060 3.72 2.60
3
CX34−62C−6F
2
49L25
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
42,000
41,000
26,000 15.00 12.50 8.50 7.70 3360 3230 2915 3.72 2.62 CX34−49C−6F
4
G60UHV−60C−090
2
49L25
42,000
41,000
26,000 15.00 13.00 9.00 7.70 3360 3165 2865 3.80 2.66 CX34−60D−6F
4
G60UHV−60D−135
2
49L25
42,000
41,000
26,200 14.50 12.00 8.20 7.50 3500 3310 2990 3.64 2.56 CX34−49C−6F
4
G61MPV−60C−091
2
49L25
42,000
41,500
26,200 14.50 12.00 8.20 7.50 3500 3285 2975 3.70 2.58 CX34−49C−6F
4
G61MPV−60C−090
2
49L25
42,000
41,500
26,200 14.50 12.00 8.20 7.50 3500 3285 2975 3.70 2.58 CX34−49C−6F
4
G71MPP−60C−090
2
49L25
42,000
41,500
26,400 14.00 12.00 8.20 7.50 3500 3315 3010 3.66 2.56 CX34−49C−6F
4
G61MPV−36C−090
2
49L25
42,000
41,500
26,400 14.00 12.00 8.20 7.50 3500 3315 3010 3.66 2.56 CX34−49C−6F
4
G71MPP−36C−090
2
49L25
42,500
41,000
26,200 14.50 12.00 8.50 7.70 3540 3250 2945 3.70 2.60 CX34−49C−6F
4
G60UHV−60C−110
2
49L25
42,500
41,000
26,200 15.00 13.00 9.00 7.70 3400 3160 2875 3.80 2.66 CX34−62D−6F
4
G60UHV−60D−135
2
49L25
42,500
41,500
26,200 14.50 12.00 8.50 7.70 3540 3195 2920 3.80 2.62 CX34−60D−6F
4
G61MPV−60D−135
2
49L25
42,500
41,500
26,200 14.50 12.00 8.50 7.70 3540 3195 2920 3.80 2.62 CX34−60D−6F
4
G71MPP−60D−135
2
49L25
42,500
41,500
26,200 15.00 13.00 9.00 7.70 3400 3190 2915 3.82 2.64 CX34−62D−6F
4
G61MPV−60D−135
2
49L25
42,500
41,500
26,200 15.00 13.00 9.00 7.70 3400 3190 2915 3.82 2.64 CX34−62D−6F
4
G71MPP−60D−135
2
49L25
42,500
41,500
26,200 14.50 12.00 8.20 7.50 3540 3265 2960 3.72 2.60 CX34−49C−6F
4
G61MPV−60C−110
2
49L25
42,500
41,500
26,200 14.50 12.00 8.20 7.50 3540 3265 2960 3.72 2.60 CX34−49C−6F
4
G71MPP−60C−110
2
49L25
42,500
41,500
26,200 14.50 12.00 8.20 7.50 3540 3275 2970 3.72 2.58 CX34−49C−6F
4
G61MPV−60C−111
2
49L25
42,500
41,500
26,400 14.50 12.00 8.50 7.70 3540 3180 2885 3.82 2.68 CX34−62C−6F
4
G61MPV−60C−091
2
49L25
43,000
41,500
26,200 15.00 13.00 9.00 8.00 3440 3105 2810 3.92 2.74 CX34−62C−6F
4
G60UHV−60C−090
2
49L25
43,000
41,500
26,400 15.00 13.00 9.00 7.70 3440 3130 2840 3.88 2.72 CX34−62C−6F
4
G60UHV−60C−110
2
49L25
43,000
42,000
26,600 15.00 12.50 8.50 8.00 3440 3150 2895 3.90 2.70 CX34−62C−6F
4
G61MPV−60C−111
2
49L25
43,000
42,000
26,600 15.00 12.50 8.50 8.00 3440 3140 2880 3.92 2.70 CX34−62C−6F
4
G61MPV−60C−110
2
49L25
43,000
42,000
26,600 15.00 12.50 8.50 8.00 3440 3140 2880 3.92 2.70 CX34−62C−6F
4
G71MPP−60C−110
2
49L25
43,000
42,000
26,600 14.50 12.00 8.50 7.70 3585 3190 2905 3.86 2.68 CX34−62C−6F
4
G61MPV−36C−090
2
49L25
43,000
42,000
26,600 14.50 12.00 8.50 7.70 3585 3190 2905 3.86 2.68 CX34−62C−6F
4
G71MPP−36C−090
2
49L25
43,000
42,000
26,400 14.50 12.00 8.50 7.70 3585 3160 2870 3.90 2.70 CX34−62C−6F
4
G61MPV−60C−090
2
49L25
43,000
42,000
26,400 14.50 12.00 8.50 7.70 3585 3160 2870 3.90 2.70 CX34−62C−6F
4
G71MPP−60C−090
2
49L25
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.