TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump
/ Page 16
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA048H4
4 TON
Horizontal Indoor Coils
Horizontal Coils
48,000
46,500
30,400 13.00 11.00 7.70 6.70 4365 4005 3675 3.40 2.42
3
CH33−60D−2F
2
91M02
48,500
47,000
30,400 13.00 11.00 7.70 6.70 4410 3995 3655 3.44 2.44
3
CH33−62D−2F
2
91M02
48,500
47,000
30,400 13.00 11.00 7.70 6.70 4410 3965 3645 3.48 2.44
3
CH33−50/60C−2F
2
91M02
49,000
48,000
30,800 13.00 11.00 7.70 6.70 4455 3775 3510 3.72 2.56
3
CH23−68
2
91M02
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
48,500
46,000
29,600 14.50 12.00 8.20 7.20 4040 3800 3465 3.54 2.50 CH33−60D−2F
4
G60UHV−60D−135
2
91M02
48,500
46,000
29,800 14.00 12.00 8.20 7.20 4040 3835 3505 3.52 2.48 CH33−60D−2F
4
G61MPV−60D−135
2
91M02
48,500
46,000
29,800 14.00 12.00 8.20 7.20 4040 3835 3505 3.52 2.48 CH33−60D−2F
4
G71MPP−60D−135
2
91M02
49,000
46,000
29,600 14.50 12.00 8.20 7.20 4085 3790 3445 3.56 2.52 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
49,000
46,000
29,800 14.00 12.00 8.20 7.20 4085 3825 3485 3.52 2.50 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
49,000
46,000
29,800 14.00 12.00 8.20 7.20 4085 3825 3485 3.52 2.50 CH33−62D−2F
4
G71MPP−60D−135
2
91M02
49,000
46,500
30,000 14.00 12.00 8.20 7.20 4085 3820 3505 3.56 2.50 CH33−50/60C−2F
4
G60UHV−60C−090
2
91M02
49,000
46,500
30,000 14.00 12.00 8.20 7.20 4085 3840 3520 3.54 2.50 CH33−50/60C−2F
4
G60UHV−60C−110
2
91M02
49,000
46,500
30,200 14.00 12.00 8.20 7.20 4085 3880 3560 3.52 2.48 CH33−50/60C−2F
4
G61MPV−60C−090
2
91M02
49,000
46,500
30,200 14.00 12.00 8.20 7.20 4085 3880 3560 3.52 2.48 CH33−50/60C−2F
4
G71MPP−60C−090
2
91M02
49,000
46,500
30,200 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CH33−50/60C−2F
4
G61MPV−60C−110
2
91M02
49,000
46,500
30,200 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CH33−50/60C−2F
4
G71MPP−60C−110
2
91M02
49,000
46,500
30,200 14.00 12.00 8.20 7.20 4085 3880 3560 3.52 2.48 CH33−50/60C−2F
4
G61MPV−60C−111
2
91M02
49,000
47,000
30,400 14.00 12.00 8.20 7.20 4085 3915 3600 3.52 2.48 CH33−50/60C−2F
4
G61MPV−60C−091
2
91M02
49,500
47,000
30,000 14.50 12.00 8.20 7.20 4125 3565 3315 3.86 2.66 CH23−68
4
G60UHV−60C−090
2
91M02
49,500
47,000
30,000 14.50 12.00 8.20 7.20 4125 3585 3320 3.84 2.64 CH23−68
4
G60UHV−60C−110
2
91M02
49,500
47,000
30,000 14.50 12.00 8.20 7.20 4125 3575 3310 3.86 2.66 CH23−68
4
G61MPV−60D−135
2
91M02
49,500
47,000
30,000 14.50 12.00 8.20 7.20 4125 3575 3310 3.86 2.66 CH23−68
4
G71MPP−60D−135
2
91M02
49,500
47,000
30,200 14.50 12.00 8.20 7.20 4125 3625 3360 3.80 2.64 CH23−68
4
G61MPV−60C−090
2
91M02
49,500
47,000
30,200 14.50 12.00 8.20 7.20 4125 3625 3360 3.80 2.64 CH23−68
4
G71MPP−60C−090
2
91M02
49,500
47,000
30,200 14.50 12.00 8.20 7.20 4125 3610 3345 3.82 2.64 CH23−68
4
G61MPV−60C−110
2
91M02
49,500
47,000
30,200 14.50 12.00 8.20 7.20 4125 3610 3345 3.82 2.64 CH23−68
4
G71MPP−60C−110
2
91M02
49,500
47,500
30,200 14.50 12.00 8.20 7.20 4125 3625 3360 3.84 2.64 CH23−68
4
G61MPV−60C−111
2
91M02
49,500
47,500
30,400 14.00 12.00 8.20 7.20 4125 3665 3410 3.80 2.62 CH23−68
4
G61MPV−60C−091
2
91M02
50,000
47,000
29,800 15.00 13.00 9.00 7.50 3845 3530 3290 3.90 2.66 CH23−68
4
G60UHV−60D−135
2
91M02
TPA060H4
5 TON
Air Handlers
Air Handlers
56,000
55,000
35,600 14.00 11.50 8.20 7.50 4870 4640 4135 3.48 2.52
4
CBX32MV−048 (Multi−Position)
Factory TXV
56,500
54,500
35,400 14.00 11.50 8.20 7.20 4915 4840 4305 3.30 2.40
4
CBX32MV−068 (Multi−Position)
Factory TXV
56,500
55,000
35,800 14.00 11.50 8.20 7.50 4915 4665 4195 3.46 2.50
4
CBX32M−060 (Multi−Position)
Factory TXV
56,500
55,000
35,800 14.00 11.50 8.20 7.50 4915 4680 4215 3.44 2.48
4
CBX32MV−060 (Multi−Position)
Factory TXV
58,500
55,000
35,800 14.00 12.00 8.20 7.50 4875 4610 4120 3.50 2.54
5
CBX26UH−060 (Up−Flow / Horizontal)
Factory TXV
59,000
55,500
36,000 15.00 12.50 8.50 7.70 4720 4585 4055 3.54 2.60
4
CBX27UH−060 (Up−Flow / Horizontal)
Factory TXV
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.