TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump
/ Page 13
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA042H4
3.5 TON
Down−Flow Indoor Coils
Down−Flow Coils
41,500
42,500
27,200 13.00 11.00 7.70 6.70 3775 3340 3055 3.72 2.60
3
CR33−50/60C−F
2
49L25
41,500
42,500
27,200 13.00 11.00 7.70 6.70 3775 3340 3055 3.72 2.60
3
CR33−60D−F
2
49L25
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
41,500
41,500
26,200 14.50 12.00 8.50 8.00 3460 3100 2805 3.92 2.74 CR33−50/60C−F
4
G60DFV−60C−110
2
49L25
41,500
41,500
26,200 14.50 12.00 8.50 8.00 3460 3085 2790 3.94 2.74 CR33−60D−F
4
G60DFV−60D−135
2
49L25
41,500
41,500
26,400 14.00 12.00 8.50 7.70 3460 3170 2875 3.84 2.68 CR33−50/60C−F
4
G61MPV−60C−091
2
49L25
41,500
42,000
26,400 14.50 12.00 8.50 7.70 3460 3150 2860 3.90 2.70 CR33−50/60C−F
4
G61MPV−60C−090
2
49L25
41,500
42,000
26,400 14.50 12.00 8.50 7.70 3460 3150 2860 3.90 2.70 CR33−50/60C−F
4
G71MPP−60C−090
2
49L25
41,500
42,000
26,600 14.00 12.00 8.50 7.70 3460 3180 2895 3.88 2.70 CR33−50/60C−F
4
G61MPV−36C−090
2
49L25
41,500
42,000
26,600 14.00 12.00 8.50 7.70 3460 3180 2895 3.88 2.70 CR33−50/60C−F
4
G71MPP−36C−090
2
49L25
42,000
41,500
26,200 14.50 12.00 8.50 8.00 3500 3080 2795 3.94 2.74 CR33−50/60C−F
4
G60DFV−60C−090
2
49L25
42,000
41,500
26,400 14.50 12.00 8.50 8.00 3500 3095 2815 3.92 2.74 CR33−60D−F
4
G61MPV−60D−135
2
49L25
42,000
41,500
26,400 14.50 12.00 8.50 8.00 3500 3095 2815 3.92 2.74 CR33−60D−F
4
G71MPP−60D−135
2
49L25
42,000
42,000
26,400 14.50 12.00 8.50 8.00 3500 3125 2845 3.94 2.72 CR33−50/60C−F
4
G61MPV−60C−110
2
49L25
42,000
42,000
26,400 14.50 12.00 8.50 8.00 3500 3125 2845 3.94 2.72 CR33−50/60C−F
4
G71MPP−60C−110
2
49L25
42,000
42,000
26,600 14.50 12.00 8.50 8.00 3500 3140 2860 3.92 2.72 CR33−50/60C−F
4
G61MPV−60C−111
2
49L25
Horizontal Indoor Coils
Horizontal Coils
41,500
42,000
26,800 13.00 11.00 7.70 6.70 3775 3485 3165 3.54 2.48
3
CH33−43C−2F
2
49L25
41,500
42,000
26,800 13.00 11.00 7.70 6.70 3775 3460 3145 3.56 2.50
3
CH33−60D−2F
2
49L25
41,500
42,000
27,000 13.00 11.00 7.70 6.70 3775 3470 3145 3.54 2.52
3
CH33−62D−2F
2
49L25
42,000
42,000
27,000 13.00 11.00 7.70 6.70 3820 3420 3120 3.60 2.54
3
CH33−50/60C−2F
2
49L25
42,000
42,500
27,200 13.00 11.00 7.70 6.70 3820 3275 3025 3.80 2.64
3
CH23−68
2
49L25
42,000
42,500
27,000 13.00 11.00 7.70 6.70 3820 3395 3095 3.66 2.56
3
CH33−43B−2F
2
49L25
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
42,000
41,000
25,800 15.00 13.00 9.00 7.70 3360 3185 2865 3.78 2.64 CH33−60D−2F
4
G60UHV−60D−135
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3215 2905 3.74 2.62 CH33−60D−2F
4
G61MPV−60D−135
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3215 2905 3.74 2.62 CH33−60D−2F
4
G71MPP−60D−135
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3230 2905 3.72 2.62 CH33−62D−2F
4
G61MPV−60D−135
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3230 2905 3.72 2.62 CH33−62D−2F
4
G71MPP−60D−135
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3240 2910 3.70 2.62 CH33−43C−2F
4
G60UHV−60C−090
2
49L25
42,000
41,000
26,000 14.50 12.00 8.20 7.50 3500 3260 2950 3.68 2.58 CH33−43C−2F
4
G60UHV−60C−110
2
49L25
42,000
41,000
26,000 15.00 13.00 9.00 7.70 3360 3200 2870 3.76 2.66 CH33−62D−2F
4
G60UHV−60D−135
2
49L25
42,000
41,000
26,200 14.50 12.00 8.20 7.50 3500 3300 2970 3.64 2.58 CH33−43C−2F
4
G61MPV−60C−090
2
49L25
42,000
41,000
26,200 14.50 12.00 8.20 7.50 3500 3300 2970 3.64 2.58 CH33−43C−2F
4
G71MPP−60C−090
2
49L25
42,000
41,000
26,200 14.50 12.00 8.20 7.50 3500 3320 2980 3.62 2.58 CH33−43C−2F
4
G61MPV−60C−091
2
49L25
42,000
41,500
26,200 14.00 12.00 8.20 7.50 3500 3325 3000 3.66 2.56 CH33−43C−2F
4
G61MPV−36C−090
2
49L25
42,000
41,500
26,200 14.00 12.00 8.20 7.50 3500 3325 3000 3.66 2.56 CH33−43C−2F
4
G71MPP−36C−090
2
49L25
42,000
41,500
26,200 14.00 12.00 8.20 7.50 3500 3330 3010 3.66 2.54 CH33−48C−2F
4
G61MPV−60C−110
2
49L25
Horizontal Indoor Coils + Furnaces
Continued on Next Page
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.