49
4.
During commissioning you will end that process with the
dealer control
center
screen. From there touch
equipment
to modified any system or
equipment settings.
5.
Select
Balance Point Control
and touch
edit
. Use the down arrow to
touch Enabled. A pop-up warning screen indicating that due to enabling
Balance Point Control other related parameter values were automatically
changed.
6.
Complete
Balance Point Control
by editing the
High
and
Low Balance
Points
. It is not necessary to change the defaults.
7.
From the equipment list, touch
air handler
. From this air handler screen
you will have access to the various airflow settings. Set the system air
volumes according to the needs of the home.
8.
When all CFM settings are complete, touch the back arrow (<) at the top
left-hand of the screen to return to the
dealer control center
. Touch
tests
to access the test section.
9.
Here you will have the opportunity to adjust blower circulation, heating
and cooling circulation air flows. Use the plus or minus buttons to adjust
up or down the CFM settings. Once adjustments are completed, touch
continue
.
10.
Under the
select test to run
screen, you may un-check any test not
required, or run all tests. Touch
start tests
to proceed. Once each test
section is completed, touch
continue
to proceed to the next group of tests.
11.
Once all tests are completed, touch
done
. This will return you to the
select
tests to run
screen. If finish, touch the back arrow (<) at the top left-hand
of the screen to return to the
dealer control center
.
12.
Touch
exit
to return to the home screen.
Hybrid System Configurations
Communicating Furnace and Conventional Air Conditioner
An communicating furnace (G71MPP, EL296V, SLP98 and SL280) with a
conventional non-communicating Lennox brand air conditioner.
1.
Wiring — See “Terminals and Wiring Recommendations” on page 5
and “Application Wiring” on page 7.
2.
Cut option link
2-stage compr
(Y1 to Y2, W915) on furnace control on two-
stage Lennox brand conventional air conditioner units only.
3.
After the entire system is wired, power up the system; the thermostat will
check the system for installed communication devices.
4.
During commissioning you will arrive at the
equipment found
screen. From
there touch
non-communicating equipment
to add non-communicating
equipment.
5.
From the add/remove equipment screen, touch either
1 Stage A/C uni
t or
2 Stage A/C unit
.
6.
Touch
done
to return to the
equipment found
screen.
7.
Touch
continue
to proceed to the next screen.
8.
From the equipment list, touch
Furnace
. From this furnace screen you will
have access to the various airflow settings. Set the system air volumes
according to the needs of the home.
9.
Continue with the commissioning sequence. When the
set up airflow
per zone
screen appears you can adjust the blower, heating and cooling
circulation air flows per zone. When done, touch
continue
to proceed.
10.
The
dealer control center
will appear. Touch
tests
to access the test
section.
11.
Here you will have the opportunity to adjust blower circulation, heating
and cooling circulation air flows. Use the plus or minus buttons to adjust
up or down the CFM settings. Once adjustments are completed, press
continue
.
12.
Under the
select test to run
screen, you may un-check any tests not
required, or run all tests. Touch
start tests
to proceed. Once each test
section is completed, touch
continue
to proceed to the next group of tests.
13.
Once all tests are completed, touch
done
. This will return you to the touch
tests to run screen. If finish, touch the back arrow (<) at the top left-hand of
the screen to return to the
dealer control center
.
14.
Touch
exit
to return to the home screen.
TIPS
If the thermostat’s
select mode
screen has only
heat only
or
off
selections
and no choice for cooling or heat/cool you must add the non-communicating air
conditioning unit. Use the following procedures from the home screen to add a
non-communicating air conditioner.
1.
Select
menu
>
settings
>
advance settings
>
view dealer control
center
>
equipment
.
2.
Select either
1-Stage A/C
or
2-Stage A/C
. Touch the back arrow (<) at the
top left-hand of the screen to return to the dealer control center.
3.
Touch
exit
to return to the home screen.
On two-stage air conditioners you must cut the
W915 2 Stage Compr
link on
the furnace control
Communicating Furnace and Conventional Heat Pump Unit (Dual