42
Table 15. Utilities
Parameter
Description
Restart smart hub
Restarts the smart hub.
Re-configure
System
Re-configure HVAC system.
Reset HVAC
Equipment
Resets all HVAC equipment.
Factory Reset
Thermostat
Resets thermostat to factory default settings.
Factory Reset
smart hub
Resets smart hub parameters back to factory default.
Tests
Verify Airflow Per Zone is the first screen to appear under this selection. If
no zoning is installed, zone airflow settings will be for zone 1 only. If zoning
equipment is detected by the system then zones 1 through 4 will be listed.
These screens allow for verification and modification of CFMs for blower,
heating and cooling circulation. Touch continue to proceed to the next screen.
Figure 20. PureAir
S
Performance Status Screen
Select
Test Mode
is the next screen to appear. Your options are automated
tests or manual tests. Select the desired option and select
apply
.
•
Automated Tests
: Select this options and the next screen will allow you to
select the specific tests available for your hardware configuration. The test
are automatic and no installer / service technician’s attendance is required.
When the automatic testing is complete the system returns to the consumer
home screen. A updated installation report is generated and available in
Lennox Pros under the Homeowners account.
•
Manual Test
: Depending on hardware present, various tests are available.
By default all items to be tested are enabled. Selecting a specific test will un-
check the item. When a specific set of tests are completed the results will be
displayed on the screen next to the tested item. Touch continue to proceed to
the next set of test items. Once all tests are completed press done to return
to the touch tests to run screen. Touch the left arrow at the top left side of
screen to return to the Dealer Control Center
Diagnostics
This screen allows the installer to test all major communicating components
of the system indoor unit (air handler or furnace), outdoor unit (air conditioner
or heat pump) and zoning control (if applicable). Pressing the stop diagnostics
button will pause the diagnostic function.
Touch the left arrow at the top left side of screen to return to the Dealer Control
Center.
Installation Report
The overview screen provides information on dealer and customer information.
Also included under day of install section is information on conditions at the time
of installation. Information includes date, time indoor and outdoor temperatures