17
7.4 Supervision mode
LED: acoustical monitoring inactive
LED: acoustical monitoring activated
LED: inactive mode
7.5 Alarm
7.5.1 .. independent of alarm unit state (armed or disarmed)
active on
„Default value“
1)
Cause of alarm
I
II
III
Entry-Delay
Connection mode
Announcement
Emergency (Sensor-2)
2)
Delayed
„Emergency call activated“
Sensor-3
3)
Un-delayed
„Alarm due to sensor 3“
1.) Default values without en without consideration of user specific programming in accordance to section 5
2.) Emergency call activation according to section 5.2.2: An emergency call will be triggered, if the button has been
activated for one second. After a pre alarm period of 20 seconds
starts dialling calling number(s) and a
hands-free connection
is established. During the pre warning period the alarm can be cancelled by pressing the
emergency button respectively by pressing key
0
.
.
3.) Sensor-3 activation according to 5.3.1.
7.5.2 .. only if alarm unit is armed
active on
„Default value“
1)
Cause of alarm
I
II
III
Entry-Delay
Connection mode
Announcement
Sensor 1
4)
Un-delayed
„Alarm due to sensor 1“
Presence verification
5)
10 Minutes/30
Seconds
„Alarm due to presence
verification
“
Sensor 2
6)
Un-delayed
„Alarm due to sensor 2“
Noise (Babyphone)
7)
Un-delayed
„Alarm due to noise“
Mains power loss
1 Minute
„Alarm due to power failure “
4.) Sensor-1 activation according to 5.1.1.
5.) Sensor-1 can be used to verify if a person is present (
section 5.1.2), i.e. an alarm will be triggered if no motion is
detected within 24h. Before starting the alarm there is a pre warning period of ten minutes. If activation is detected
(motion detected or emergency button pressed) within this period, the alarm is cancelled, otherwise
establishes a
hands-free connection
6.) Sensor-2 activation according to 5.2.1.
7.) Noise monitoring according to 5.4: To avoid false alarm while acoustical monitoring, close windows and try to
eliminate sources of noise.
8.)
EasyAlarm
®
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes (=> time-out
according to section 10.4). During a pre warning period of 1 minute the following message is announced „Alarm due
to power failure“. After this period
dials the programmed number and a
hands-free connection
is
established. If
does not detect mains power during start up the monitoring remains inactive => „Power
failure“ is announced ! As soon as mains power is detected,
starts to supervise mains power
7.5.2.1
alarm release renewed
After an alarm
remains inactive during a waiting period of two minutes. Only if at expiration of this
waiting period an alarm event occurs again, a new alarm is released.
Note:
After an alarms through to sensor-1/2/3 a renewed alerting comes off only if to the alarm contact returned to the state
of rest.
7.6 Alarm delay / Pre warning period / Entry delay
An alarm can be delayed due to following reasons:
An alarm sensor in the area of the entrance must be delayed to have enough time to switch off the supervision mode
before
dials the first calling number.
A pre warning announcement is used to avoid false alarms (i.e. technical error like power failure, unwanted
emergency calls). During the pre warning period the alarm can be cancelled by pressing the emergency button
respectively by pressing key
0
.
.
Announcement:
„Alarm acknowledged“
Notes:
The entry/exit period can be adjusted according to section 10.3.
If an alarm has been triggered by pressing the emergency button, cancellation of the alarm is only possible, if the
button has been released for min. 3 seconds before pressing it again.
7.6.1 Siren activation during pre warning period
If you use a siren (
section 11.2) which is activated as described in section 10.5.2, the pre alarm period is signalled by a
periodical siren tone.
Noise
Nois
4 seconds
4 seconds
4 seconds
4 seconds