5. CONFIGURATION OF THE ALARM REGISTERS
5.1 Sensor-1 monitoring
5.1.1 Sensor-1 as alarm contact
EasyAlarm
®
auto-detects a Plug&Protect-sensor and starts its monitoring if the system is armed. You can define the
behaviour for sensor-1 as following:
Example: A normally closed contact shall trigger an un-delayed alarm with a
hands-free-connection
independent from
position of the selection switch.
1.
Slide
function switch
to PROG
2.
Enter sequence
*
.
9
.
3
.
1
.
7
5 6
#
.
#
.
. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3.
If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
.
4.
Enter sequence
0
.
0
.
1
.
0 0 0
.
1
.
1
.
.
R-Siren
Entry-Delay Connect. mode
Sensor on..
Type
0: off
0:off
0: Listening-in
I / II / III
00: inactive
1: on
1:on
1: Hands-free
0 0
0
01: Normally open contact
0: enabled
10: Plug&Protect (auto-detected at power-on)
1: disabled
input-2 is open => Normally open monitoring
input-2 is closed => Normally closed monitoring
5.
Press key
#
.
.
11: Normally closed contact
The new register (bit 7 -> bit 0) will be announced
6.
Slide
function switch
to OFF
5.1.2 Sensor-1 for presence verification
You can also use sensor-1 to monitor missing activity (i.e. no motion detected within a certain period) => Alarm message:
„Emergency call due to sensor-1“. Therefore you have to activate time-out as below.
5.1.2.1
How to program presence verification time-out
Time-out for presence verification is factory set to 24h. If there is no activation within this period, an alarm is triggered
after a pre warning period of 10 minutes (this period is indicated with a periodical loud beep tone).
1.
Shift
function switch
to PROG
2.
Enter
*
.
9
.
7
.
1
.
3
6 7
#
.
#
.
.
Current register value <n> will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3.
If you want to keep current value proceed with step 4. Otherwise modify register with
*
.
New value <
n>
#
.
.
The new register value <n> will be announced
4.
Shift
function switch
to OFF
<n>
Explanation
0
Presence verification is switched off
(=Factory setting)
6..255
Time-out in steps of 10 min. (min. 60min, max. 42.5h) => For example: n=144 (144*10min = 24 h)
5.1.3 Sensor-1 as entry-detector (Gong function)
A sensor-1 activity can also be signalled locally (Gong-function) according to the following procedure:
Example: Sensor-1 shall greet an incoming person with the pre-recorded individual message only on position I.
1.
Slide
function switch
to PROG
2.
Enter sequence
*
.
9
.
3
.
1
.
7
3 1
#
.
#
.
..
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3.
If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
.
4.
Enter sequence
0
.
0
.
0
.
0 1 1
.
1
.
0
.
.
Unused
Gong on..
Gong-type
000:
I / II / III
00: Gong
0 1
1
01: --
0: enabled
10: Individual message
1: disabled
11: Beep loud
5.
Press key
#
.
.
The new register (bit 7 -> bit 0) will be announced
6.
Slide
function switch
to OFF
Factory default for sensor-1 monitoring
00 0 000 10, => un-delayed alarm in listening-in
connection only on all positions I/II/III
=> connector type: auto-type (plug&protect)
Factory default for gong-function sensor-1
000 111 00
Note:
If you do not want to
trigger an alarm on
position I you have to
disable alarm according to
section 5.1.1