12
5.3 Sensor-3 monitoring
5.3.1 Sensor-3 as alarm contact
Note: if sensor-3 input is enabled as show below, you cannot disarm at any time!
Example: A normally closed contact shall trigger an un-delayed alarm with a
hands-free-connection
independent from
position of the selection switch.
1.
Shift
function switch
to PROG
2.
Enter sequence
*
.
9
.
3
.
1
.
7
6 1
#
.
#
.
.
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3.
If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
4.
Enter sequence
0
.
0
.
1
.
0 0 0
.
1
.
1
.
.
R-Siren
Entry-Delay Connect. mode
Sensor on..
Type
0: off
0:off
0: Listening-in
I / II / III
00: inactive
1: on
1:on
1: Hands-free
0 0
0
01: Normally open contact
0: enabled
10: Plug&Protect (auto-detected at power up)
1: disabled
input-3 is open => Normally open monitoring
input-3 is closed => Normally closed monitoring
11: Normally closed contact
5.
Press key
#
.
.
The new register (bit 7 -> bit 0) will be announced
6.
Shift
function switch
to OFF
5.4 Acoustical monitoring
The acoustical monitoring is enabled if
selection switch
is on position III. In case the alarm conditions is fulfilled a
listening-in connection
is established without any delay If you want to change this factory default you can proceed as
following:
Example: Acoustical monitoring enabled on II and III starting a hands-free connection without delay.
1.
Shift
function switch
to PROG
2.
Enter sequence
*
.
9
.
3
.
1
.
7
5 9
#
.
#
.
.
Current register (bit 7 -> bit 0) will be announced followed by “to modify press
*
.
, to stop press
#
.
“
3.
If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing
*
.
.
4.
Enter sequence
0
.
0
.
1
.
1 0 0
.
0
.
1
.
.
R-Siren
Entry-Delay Connect. mode
Sensor on..
Type
0: off
0:off
0: Listening-in
I / II / III
00: Monitoring independent from arm/disarm state
1: on
1:on
1: Hands-free
1 0
0
01: Monitoring only in armed state
0: enabled
1: disabled
5.
Press key
#
.
.
The new register (bit 7 -> bit 0) will be announced
6.
Shift
function switch
to OFF
The sensitivity of the acoustical monitoring depends on selected position of the selection switch:
Position
Alarm conditions (
auf ON)
I
Low sensitivity (LOW) => Alarm will be triggered if the noise level exceeds several times within a long
period (approx. 8 activations)
II
Medium sensitivity (MED)
III
Highest sensitivity (HIGH) => Alarm will be triggered if the noise level exceeds a few times within a short
period (approx. 3 activations)
Factory default for sensor-3 monitoring
00 0 111 00, => inactive on all positions I/II/III
Factory default for acoustical monitoring
00 0 110 01, => un-delayed alarm in listening-in
connection only on position III, inactive if disarmed