25
10.5.2 .. through external siren
Operating mode of the siren can be programmed as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
0 7
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
No signalisation by the siren
(=factory setting)
1
periodical signalisation of the delay for exit / entry
2
periodical signalisation of the delay for exit / entry
permanent siren tone in case of an alarm during
listening-in connection
(exception: silent panic call)
10.5.3 .. during phone connection (announcements)
The cause of alarm will be repeated every 8 seconds during connection until a DTMF command is received. This
corresponding register
2 0
can be read out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
2 0
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
no repetitions => one announcement a the beginning of the connection
1..254
Cycle of repetition in steps of seconds
(factory setting=8)
i.e:
Value
=30
announcement every 30 seconds
255
Special case:
Individual message
announced just once (
WITHOUT
cause of alarm)
10.6 Shared line with telephone/modem
If you want to use
EasyAlarm
®
in combination with a downstream telephone/modem you must set dialling delay as
follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
2 4
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
<
n>
Comments
0
No dialling delay
(
=factory setting
)
1
Dialling delayed
(=Option PLUS)
10.6.1 Wiring with cord with end-sleeves
10.6.2 Wiring Switzerland with T+T- SW06
1.
Plug adapter SW06 into wall plate
2.
Connect FCC-cord between alarm unit and adapter SW06
3.
Plug „post connected” phone into T+T-Jack of adapter SW06
10.6.3 Wiring Germany with TAE-N-Plug
1.
Plug adapter TAE-N into first N-Jack of wall plate
2.
Connect FCC-cord between alarm unit and adapter TAE-N
3.
Plug „post connected” phone into TAE-F-Type-Jack of wall plate
Value
Value
Value
post connected phone
post connected phone
TAE-N-Plug
-LINE
End-sleeves of telephone cord
PIN 2: OUT
Black =>
to downstream modem/phone b’
PIN 3: IN
Red <= from PSTN (Terminal a)
PIN 4: IN
Green <= from PSTN (Terminal b)
PIN 5:OUT
Gelb =>
to downstream modem/phone a’
PSTN
IN
OUT
TAE-F-Plug