63
Programs
Leica TPS800-4.0.0en
Warnings / Messages
Important messages
Meaning
Selected point has no valid data!
This message occurs if the selected target point has no easting or northing
coordinate.
Max 10 points supported!
If 10 points have already been measured and another point is selected. The
system supports a maximum of 10 points.
Invalid data - no position computed!
The measurements may not allow final station coordinates (Eastings, North-
ings) to be computed.
Invalid data - no height computed!
Either the target height are invalid or insufficient measurements are available
to compute a final station height.
Insufficient space in job!
The present selected job is full and does not allow further storage.
Hz (I - II) > 0.9 deg, measure point again!
This error occurs if a point was measured in one face and the measurement
in the other face differs by more than 180° ±0.9° for the horizontal angle.
V (I - II) > 0.9 deg, measure point again!
This error occurs if a point was measured in one face and the measurement
in the other face differs by more than 360° - V ±0.9° for the vertical angle.
More points or distance required!
There is insufficient data measured to be able to compute a position. Either
there are not enough points used or not enough distances measured.