60
Programs
Leica TPS800-4.0.0en
[AddPt]
Input another backsight point.
[COMPUTE]
Calculates and displays the station
coordinates, if at least 2 points and
a distance were measured.
3/I
Indicates that the third point in tele-
scope position I was measured.
3/I II
Indicates that the third point in tele-
scope positions I and II.
Results
Displays calculated station coordinates:
[PREV]
Switches to measurement display,
to measure additional points.
[RESID]
Displays residuals.
[StdDev]
Displays standard deviation.
[OK]
Sets the displayed coordinates and
instrument height as new station.
)
If the instrument height was set to 0.000 in
the setup screen, then the station height refers to
height of trunnion axis.
PREV
RESID StdDev
OK
STATION COORDINATES
Station :
100
hi :
1.500
EO : 100.506
NO : 100.040
HO : 99.999