19
9.8
SET RATIO
Sets the manual control resolution
Command code:
71 033
Parameter:
2 bytes
1 = fine resolution
32 = coarse resolution
Range :
1 to 32
Return:
none
Comment:
Changes the resolution of the manual control unit. A low speed is obtained with the fine resolution
and a higher speed with the coarse resolution.
9.9
GET RATIO
Retrieves the manual control resolution
Command code:
71 034
Parameter:
none
Return:
2 bytes
1 = fine resolution
32 = coarse resolution
Range :
1 to 32
Comment:
Changes the resolution of the manual control unit. A low speed is obtained with the fine resolution
and a higher speed with the coarse resolution.
9.10 GET KEY STATE
Queries whether a key has been pressed
Command code:
71035
Parameter
none