88
Station Setup, for Builder R, RM,
M power and RM power
9.2.3
Establish Control Line - Anywhere
Description
The Setup method
Establish Control Line - Anywhere
is used to set up the instru-
ment along a control line. The coordinates of line start point are set to E
0
= 0.000,
N
0
=0.000 and H
0
=0.000. The orientation is set to 0.000 in the direction of the
second line point. Furthermore line startpoint can be shifted by entering or meas-
uring line and offset values.
)
The height of line startpoint P1 is used as the reference height for all further meas-
urements.
Diagram
P0
Station
P1
Line start point
P2
Second line point
P2
P1
P0
Hz = 0.000
Summary of Contents for Builder M power