Technical Data
217
Object in shade, sky overcast.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 1 mm.
Reflector range
(fine/fast mode)
CPR105 Flat prism
(Cat-eye)
5 mm + 2 ppm
< 2
CPR105 Flat prism
(Reflective tape)
3 mm + 2ppm
< 2
Tracking
5 mm + 2 ppm
1.0
Standard measuring
Standard deviation,
ISO 17123-4
Measure time, typical [s]
Range of measurement :
1.5 m to 3500 m
Type
Range 1
Range 2
Range 3
[m]
[ft]
[m]
[ft]
[m]
[ft]
CPR111 BUILDER
prism, true-zero offset
450
1500
800
2600
1000
3500
Round prism
1800
6000
3000
10000
3500
12000