Area Room2: DMX-OUT Source = presets.
DMX layout = 5 channels, 11 – 15.
Zones can be any type. Use RGB types as needed.
2. DTM-MA has two areas: One is controlled by its presets and zones, one is controlled from a
lighting console or the station. DMX from the console does not have to be stored or recalled at
the DTM-MA, just passed through while the console is being used.
Area Lobby: DMX-OUT Source = presets.
DMX layout = 10 channels, 1 – 10.
Zones can be any type. Use RGB types as needed.
Area Stage: DMX-OUT Source = DMX-IN-then-presets
on loss of DMX-IN = last preset
enable capture = unchecked (not enabled)
DMX layout = 100 channels, 100 – 199.
Zones can be any type. Use RGB types as needed.
Operation: When the console is on, DMX-IN for area Stage will be passed through to DMX-
OUT so that the console is controlling Stage lights. When the console is off, a user can control
Stage lights from the area's presets and zones.
While DMX-IN is being passed through in area Stage, the DTM-MA user can manually
disable/enable pass-through to take control of area Stage as needed. Any time DMX-IN
transitions to 'present' (e.g., console is turned on), DMX-IN will be passed through.
3. DTM-MA has three areas. One is controlled by its presets and zones. Two areas are used to
control one space (a stage), where lights are controlled by a console or the station. The
console's output DMX can be stored and recalled by the station, as a backup for the console.
Area Lobby: DMX-OUT Source = presets.
DMX layout = 10 channels, 1 – 10.
Zones can be any type. Use RGB types as needed.
Area Stage: DMX-OUT Source = DMX-IN-then-presets
on loss of DMX-IN = last preset
enable capture = unchecked (not enabled)
DMX layout = 100 channels, 100 – 199. Overlays area Show.
Zones can be any type. Use RGB types as needed.
Area Show: DMX-OUT Source = DMX-IN-then-presets
on loss of DMX-IN = last preset
enable capture = checked (enabled)
DMX layout = 100 channels, 100 – 199. Overlays area Stage.
Zones are type 'intensity'.
Operation: When the console is on, DMX-IN for area Stage will be passed through to DMX-
OUT so that the console is controlling stage lights. To store DMX from the console, the DTM-
MA user selects area Show and stores to its presets. When the console is off, the user can
control stage lights from presets and zones in area Stage. Or, the user can recall area Show