would be 325
°
F with a standard 1.5 mil film. For the vast majority of
applications, the temperature should never be set higher than 350
°
F.
For 3 to 10 mil low-temperature films, the temperature would be in the
200-260
°
F range.
6. Turn the fan switch to the ON position. You should hear the fans begin
to operate. Turn the fan switch off.
7.
The laminating and pull rollers are shipped in the open position. Turn the
two large 3-arm knobs on the right side of the unit counter-clockwise to
close the laminating and pull rollers. Open and close both sets of rollers
several times. Notice that starting from the “open” position there is first a
“closed” position and a “closed & locked” position for laminating.
Both rollers must be in the “closed & locked” position for laminating.
Leave the rollers open if you are not going to thread the machine now.
Always shut down or ship the machine with the rollers open. Close the
rollers if you are about to thread the machine.
8. Turn the drive direction switch to the FORWARD position and turn the
drive power switch on. The pull rollers and the laminating rollers should
rotate. Turn the drive power switch off.
Unless you are going to thread the laminator now, make sure all power
switches are off, including the master switch on the back of the machine.
19