background image

   

WaveSurfer Accessory

„

 Operating Procedures 

Operate this product using the following procedures. 

(a)  Checking the Remaining Battery Charge Level of 

the BATTERY PACK 

1.  An indication switch used to check the remaining battery charge 

level is provided at the upper portion of the name label of the 
BATTERY PACK. 
(See Figure 3-1.) 
Press this switch. 

2.  Five charge LEDs are arranged on the right of the indication 

switch.  The remaining battery charge level is shown by lit or 
flashing LED lamps. 

NOTE 1  For details about description of charge LED lamp 

indications, see the section, “(C) Charge LED Lamp 
Indications”, on page 14 of the instruction manual for 
BATTERY PACK (WS-BATTERY), an optional unit 
of the oscilloscope. 

Charge LED lamps (Red ) 

Indication switch 

 

 

 

Figure 3-1    Remaining Charge Level Indication and Check 

 

11

Summary of Contents for WS-BATT-CHRG

Page 1: ...Accessory WS BATT CHRG BATTERY CHARGER User s Manual ...

Page 2: ...WaveSurfer is a trademark of LeCroy Corporation Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and other countries ...

Page 3: ...and basic usage of the BATTERY CHARGER Notes Parts of the contents of this manual may be modified without prior notice for improvements in performance and functions Reproduction or reprinting of the contents of this manual without prior permission from LeCroy is prohibited If you have questions about the BATTERY CHARGER please contact LeCroy Corporation Refer to the contact address given at the en...

Page 4: ...ARGER 1 Accessories CHARGE CONTROL cable 1 Power cord 1 User s manual 1 Sending Back for Repairs If the instrument is inoperable send it back to LeCroy Corporation Refer to the contact address given at the end of this manual We will repair it without charge as long as it is under warranty When sending back the instrument explicitly describe the following product name serial number description of t...

Page 5: ...evel of the BATTERY PACK 11 b Connecting the BATTERY PACK to the BATTERY CHARGER 12 c Turning ON the POWER Switch on the BATTERY PACK 14 d Turning ON the POWER Switch on the BATTERY CHARGER to Start Charging 14 e Completing the Charging of the BATTERY PACK 15 f Disconnecting the DC OUT Cable and CHARGE CONTROL Cable 15 Protective Functions 16 Specifications 17 a Product Specifications 1 of 2 17 b ...

Page 6: ...he accompanying information or documents in order to protect against personal injury or damage to the BATTERY CHARGER This symbol warns of a potential risk of shock hazard The CAUTION sign indicates a potential hazard It calls attention to a procedure practice or condition which if not followed could possibly cause damage to equipment If a CAUTION is indicated do not proceed until its conditions a...

Page 7: ...on Overvoltage Category II Line voltage in equipment and to wall outlet Installation Overvoltage Category I All mains isolated terminals Pollution Degree 2 Protection Class I CAUTION To avoid personal injury or damage to the BATTERY CHARGER or the BATTERY PACK connected to it review and comply with the following safety precautions Use only as intended The BATTERY CHARGER is intended to be used onl...

Page 8: ...bles Also make sure to turn off the power button before connecting to the input power source Turning on off the power switch controls the on off state of the output Always use the supplied CHARGE CONTROL cable If a cable other than the supplied CHARGE CONTROL cable this may cause an electric shock a fire or a malfunction Stop use if the BATTERY PACK is not charged fully within the normal charging ...

Page 9: ...nction an electric shock or a fire Always operate this product within a specified AC power voltage range If the input current is excessive the internal fuse is blown up to shutdown the power At this time to recover the BATTERY CHARGER it is absolutely necessary to replace the internal fuse and make the adjustment Ask LeCroy Corporation to repair the defective BATTERY CHARGER Keep product surfaces ...

Page 10: ...ubject to disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper disposal and recycling of your LeCroy product please visit www lecroy com recycle 6 ...

Page 11: ...ACK is connected to the BATTERY CHARGER WS BATT CHRG with the CHARGE CONTROL cable supplied with the BATTERY CHARGER and DC OUT cable as shown in Figure 1 below to charge the BATTERY PACK The charge output is output from the BATTERY CHARGER to the DC OUT indicated on the label connector of the BATTERY PACK through the DC OUT cable during charging Additionally the control signal is input from the B...

Page 12: ... Manual Units a BATTERY CHARGER Figure 2 1 shows the outside view of this product Top panel Side panel Front panel Side panel Rubber foot 4 locations Unit mm Name Label Rear panel Figure 2 1 Outside View of BATTERY CHARGER 8 ...

Page 13: ...is connector for charging Note Do not connect any cable other than that of the BATTERY PACK d CHARGE CONTROL connector This terminal is an input part of the BATTERY CHARGER Connect the CHARGE CONTROL cable supplied with this product to this connector for charging e POWER lamp This lamp is a power indication lamp of the BATTERY CHARGER When turning ON the POWER switch on the rear this lamp is lit i...

Page 14: ...l goes off d LINE The power cord of the BATTERY CHARGER is connected to this connector Power voltage 90 to 264 Vrms Power frequency 47 to 63 Hz e Name label LeCroy logo mark logo mark of CE UL standard BATTERY CHARGER model name power consumption manufacture No and manufacturer name are described on this name label f WARNING WARNING indication stating that only authorized service engineers are all...

Page 15: ...RY PACK See Figure 3 1 Press this switch 2 Five charge LEDs are arranged on the right of the indication switch The remaining battery charge level is shown by lit or flashing LED lamps NOTE 1 For details about description of charge LED lamp indications see the section C Charge LED Lamp Indications on page 14 of the instruction manual for BATTERY PACK WS BATTERY an optional unit of the oscilloscope ...

Page 16: ...rd to the rear panel of the BATTERY CHARGER see Figure 3 2 and another connector of the AC power cord to a commercial power outlet Figure 3 2 Connection of AC Power Cord 2 Next insert the DC OUT cable of the BATTERY PACK into the BATTERY connector at the lower left portion of the front panel of the BATTERY CHARGER See Figure 3 3 NOTE 3 At this time connect the DC OUT cable while carefully checking...

Page 17: ...CHARGE CONTROL connector female firmly Figure 3 4a Connection of DC OUT Cable Figure 3 4b Completion of Cable Connection 4 Connect the CHARGE CONTROL cable to the CHARGE CONTROL connector on the side panel of the BATTERY PACK See Figs 3 5a and 3 5b NOTE 5 Insert the connector male of the cable into the CHARGE CONTROL connector female firmly Figure 3 5a Connection of CHARGE CONTROL Cable Figure 3 5...

Page 18: ... Start Charging When pressing the I portion the POWER switch on the BATTERY CHARGER is turned ON On the contrary when pressing the O portion it is then turned OFF See Figure 3 7 Figure 3 7 POWER Switch on BATTERY CHARGER The BATTERY CHARGER now begins to charge the BATTERY PACK The POWER lamp on the front panel is lit in green and the CHARGE lamp is lit in yellow during charging The remaining batt...

Page 19: ...ime The reference charging time until the BATTERY PACK is fully charged is approximately 3 hrs It takes a relatively short time to charge the BATTERY PACK to a remaining battery charge level of 80 e Completing the Charging of the BATTERY PACK When the CHARGE lamp on the BATTERY CHARGER goes off and the charging is completed turn OFF the POWER switch on the BATTERY CHARGER f Disconnecting the DC OU...

Page 20: ...CHARGER it is necessary to replace the output fuse and make the adjustment Contact the service department of LeCroy Corporation Charge output over voltage protection If the output voltage becomes excessive for some reason the output is stopped To recover the BATTERY CHARGER it is necessary to reset the over voltage status and make the adjustment Contact the service department of LeCroy Corporation...

Page 21: ...to 63 Hz Power consumption 200 VA or less Insulation resistance 10 MΩ or more Between power input and BATTERY connector and between power input and CHARGE CONTROL connector at DC500 V 2k Vac 1 min 50 60 Hz between power input and chassis Withstanding voltage 3k Vac 1 min 50 60 Hz between power input and BATTERY connector and between power input and CHARGE CONTROL connector 1 The appearance and spe...

Page 22: ... to 50 RH at 40 o C Humidity densation 95 RH No dew con Storage non operating 5 to Upper limit derates to 50 RH above 40 C Operating Up to 6 562 ft 2 000 m Altitude 0 ft Storage non operating Up to 40 00 12 192 m General specifications 240 W 170 D 65 H mm Outside dimensions Tolerance 2 mm Length of CHARGE CONTROL cable 0 60 m 0 05 m Length of power cord 2 0 m 0 1 m Weight Approx 1 3 kg 1 The appea...

Page 23: ...8kV air discharge E of Conformity ields ode r electrical l outlet EN 61000 4 3 2002 A1 2003 RF Radiated F 3V m 80 MHz to 1 GHz 80 amplitude modulated EN 61000 4 4 2004 Electrical Fast Transient Burst 1 kV on AC mains A1 2001 Surge EN 61000 4 5 1995 1 kV differential mode 2 kV common m EN 61000 4 6 1996 A1 2001 RF Conducted Field 3 V 150 kHz to 80 MHz amplitude modulated with 1kHz sine wave 04 Main...

Page 24: ...BATTERY CHARGER User s Manual UL and cUL Listed Conforms to UL 61010 1 2nd Edition and CAN CSA C22 2 No 61010 1 04 20 ...

Page 25: ...ternet www lecroy com 2004 by LeCroy Corporation All rights reserved LeCroy ActiveDSO ProBus JitterTrack WavePro WaveMaster WaveSurfer and Waverunner are registered trademarks of LeCroy Corporation Information in this publication supersedes all earlier versions Specifications subject to change without notice ...

Page 26: ...WaveSurfer Accessory WS BATT CHRG ...

Reviews: