BATTERY CHARGER User's Manual
Protective Functions
Protective circuits for electrical connection and temperature
conditions are provided on this product. Table 4 describes the
protective functions and symptoms.
If any symptom stated in Table 4 occurs, contact LeCroy
Corporation.
Table 4 Protective Functions and Corrective Actions
<Protective function>
Description and corrective action
Charge output
over-current protection
If the output current becomes excessive for
some reason, the output fuse is blown up.
To recover the BATTERY CHARGER, it is
necessary to replace the output fuse and
make the adjustment. Contact the service
department of LeCroy Corporation.
Charge output
over-voltage protection
If the output voltage becomes excessive for
some reason, the output is stopped.
To recover the BATTERY CHARGER, it is
necessary to reset the over-voltage status
and make the adjustment. Contact the
service department of LeCroy Corporation.
Over-heat protection
If the BATTERY CHARGER is operated at
a temperature exceeding the specified
operating temperature range, the thermal
fuse is blown up to stop the output.
To recover the BATTERY CHARGER, it is
necessary to replace the thermal fuse and
make the adjustment. Contact the service
department of LeCroy Corporation.
16