²
&DSWXULQJ*OLWFKHV
Note: “
(GJH
” — for Edge
Trigger — is selected by
default. This trigger is
described by source and
coupling (see following list),
as well as slope and level
condition — the same
parameters used to build up
the SMART Trigger.
The screen will then display:
7ULJJHU6RXUFH
The trigger source may be:
À
The acquisition channel signal (CH 1, CH 2, CH 3 or CH 4)
conditioned for the overall voltage gain, coupling, and
bandwidth.
À
The line voltage that powers the oscilloscope (LINE). This
can be used to provide a stable display of signals
synchronous with the power line. Coupling and level are not
relevant for this selection.
À
The signal applied to the EXT BNC connector (EXT). This
can be used to trigger the oscilloscope within a range of
±
0.5 V on EXT and
±
5 V with EXT/10 as the trigger source.
Or, on the
LC564
AND
LC584 S
ERIES
,
±
1.2 V for EXT and
±
6 V with EXT/5 as trigger source.