41
ELD2-RS70** User Manual
4.2.6
【
Class 5
】
Extended Setup
Pr5.00
2nd numerator of electronic gear
Range
unit
default
Related
control mode
1-32767
-
1
P
S T
Pr5.01
3rd numerator of electronic gear
Range
unit
default
Related
control mode
1-32767
-
1
P
S T
Pr5.02
4th numerator of electronic gear
Range
unit
default
Related
control mode
1-32767
-
1
P
S T
Pr5.03* Denominator of pulse output division
Range
unit
default
Related
control mode
1-2500
-
2500
P
S T
According to the command pulse input , set the 2nd to 4th numerator of electronic gear
DIV1 DIV2
numerator of electronic gear
denominator of electronic gear
OFF
OFF
Pr0.09
Pr5.03
ON
OFF
Pr5.00
Pr5.03
OFF
ON
Pr5.01
Pr5.03
ON
ON
Pr5.02
Pr5.03
For details, refer to Pr0.11
.
Pr5.06
Sequence at servo-off
Range
unit
default
Related
control mode
0-1
-
0
P
S T
Specify the status during deceleration and after stop, after servo-off.
Setup value
during deceleration
After stop
0
emergency
Free-run
1
Free-run
Free-run
Pr5.08
LV trip selection at main power OFF
Range
unit
default
Related
control mode
0-1
-
0
P
S T
You can select whether or not to activate Err0d.0 (main power under-voltage protection)function
while the main shutoff continues for the setup of Pr5.09(The main power-OFF detection time).
Setup value
Action of main power low voltage protection
0
When the main power is shut off during Servo-On,Err0d.0 will not be triggered and
the driver turns to Servo-OFF. The driver returns to Servo-On again after the main
power resumption.
1
When the main power is shut off during Servo-On, the driver will trip due to
Err0d.0
Caution:
Err0d.0(main power under-voltage protection) is trigged when setup of Pr5.09 is long and
P-N voltage of the main converter falls below the specified value before detecting the main power
shutoff , regardless of the Pr5.08 setup.
Pr5.09*
The main power-OFF detection time
Range
unit
default
Related
control mode
70-2000
1ms
70
P
S T
You can set up the time to detect the shutoff while the main power is kept shut off continuously. The
main power off detection is invalid when you set up this to 2000.