62
ELD2-RS70** User Manual
⚫
Software position limit setting
⚫
Position limit deceleration settable
Remark
:
Software position limit effective after homing accomplish.
E-stop
Input E-stop signal through I/O
,
stop positioning operation.
Positioning
Select location path number by positioning address IO(AD0-3),
Then start the location path operation by activate I/O(CTRG)
⚫
Contains the positioning mode, speed mode and homing mode.
⚫
IO rising edge double edge trigger start.
⚫
Support continuous positioning
⚫
Maximum 16 segment
⚫
Position, speed, acceleration settable
⚫
Pause/timing time settable
Remark
:
Double edge trigger only effective for CTRG !
485 control
Use 485 communication to manipulate above PR working
Remark
:(
1
)
For PR mode, position command adopt unit: 10000P/r.
(
2
)
PR only effective under PR
position control mode, P0.01=0.
7.1.2 Installation wiring
IO terminal wiring and parameter configuration
:
Newly added IO of PR on the base of standard IO
Relevant parameters
:
Parameter
Name
Specification
Pr4.02-Pr4.07
DI input
selection
Specific of the 8 input terminals' function distribution
,
refer to functional
allocation table.
Pr4.10-Pr4.15
DO output
selection
Specific of the 6 output terminals' function distribution
,
refer to functional
allocation table.
IO terminal functional allocation table
:
Input
Output
Signal
name
Symbol
set value
signal
name
Symbol
set value
Normally
open
Normally
closed
Normally
open
Normally
closed
Trigger
command
CTRG
20h
A0h
Accomplish
commands
CMD_OK
20h
A0h
Homing
signal
HOME
21h
A1h
Accomplish
path
MC_OK
21h
A1h
Forced to
stop
STP
22h
A2h
Accomplish
homing
HOME_OK
22h
A2h
Positive
JOG
JOG+
23h
A3h
Torque limit
TQL
06h
86h
Negative
JOG
JOG-
24h
A4h