11.

 

USING APPLIANCE

 

 

When in use make sure that there are no flammable materials close to the 
front, sides or rear of the appliance. 

 

Always use a fire-guard if there are small children or animals in the room. 

 

Users  should  become  familiar  with  the  normal  flame  patterns  of  the  Pilot 
burner and main burners. 

 

Be aware that the Knob, on the control valve cover may become 

HOT

, when 

the appliance is in use. Gloves or tongs should be used when moving this cover 
to access the control valve knob. 

 

12.

 

VENTILATION REQUIREMENTS

 

 

There are certain important safety guidelines to be followed with regards to 
the provision of adequate ventilation for vent free appliances. These guidelines 
must be noted and the installation must adhere to these. The guidelines are 
covered in the installation code: SANS 10087-1. Your installer is required to 
install the appliance in accordance with the requirements of the code. 

 

The fireplace 

CANNOT BE INSTALLED

 in bathrooms or bedrooms! 

 

The fireplace specifically designed to be installed in an open area. 

 

There must be permanent ventilation openings in the room at floor and ceiling 
levels. These should never be blocked. These openings should supply a direct 
flow of fresh air to the areas where the appliance is installed. 

 

The minimum room volume is 35 meters cubed (35m

3

). In the case of open 

plan  layouts,  the  total  volume  of  the  combined  areas,  may  be  used  in 
determining if the minimum of 35m

is met. 

 

In addition to above general room ventilation, specific ventilation opening of 
220  x  70mm  is  required.  The  opening  must  be  directly  in  line  with  burner 
(located below the gas grate in the center).  The ventilation opening can be on 
either side of the gas grate, including exterior walls. 

 

Included with the fireplace is a single ventilation grill (250x100mm) in brushed 
stainless steel finish to cover the above opening. (See FIGURE 3 diagram).  

 

A flue or a decorative cowl may be installed over the unit. Your installer will 
advise on this. Where a cowl is used, it may be fitted with a flue if desired, but 
this is not a requirement. 
 

Summary of Contents for FGW 003

Page 1: ...Page 1 VENT FREE DROP IN GAS GRATE Installation Operating Manual Please read these instructions carefully before installation use Keep for future reference...

Page 2: ...uries or damages caused by faulty or incorrect installation or use of the appliance Model FGW 003 600mm Model FGW 004 900mm Model FGW 005 1120mm TABLE OF CONTENTS 1 WARNING INTRODUCTION P 3 2 TECHNICA...

Page 3: ...sed bedrooms and bathrooms WARNING This is a flue less gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate ventilation must be provided Refer to the appr...

Page 4: ...with a card carrying their Registration Number Ask to be shown the card before allowing the installation work to commence and make a note of the Installer QCC Number Upon completion of the installati...

Page 5: ...gas leak use a brush dipped in a soapy water solution e g water with a dishwashing detergent added and apply the solution to all the joints of the system If there is leak turn off the gas supply at th...

Page 6: ...ation requirements indicated in SECTION 12 of this booklet the specific requirement of SANS 10087 1 and any municipal by laws If installing into an existing fireplace with or without a manufactured fi...

Page 7: ...cylinder is required For optimal efficiency we recommend to use a 48Kg LPG cylinder 6 ASSEMBLEY INSTRUCTIONS Supplied with the appliance is a bag of vermiculite chips a golden noncombustible organic s...

Page 8: ...ve which automatically ignites the gas grate when the control valve knob is turned to the IGNITE position It does not require the use of a lighter of matches for ignition It also does not require batt...

Page 9: ...ection 5 9 LIGHTING THE APPLIANCE FOR THE FIRST TIME Before lighting the appliance for the first time ensure that there are no gas leaks and that a pressure test was done The installer is required to...

Page 10: ...BE INSTALLED in bathrooms or bedrooms The fireplace specifically designed to be installed in an open area There must be permanent ventilation openings in the room at floor and ceiling levels These sh...

Page 11: ...Fires SA Pty Ltd The grate body carries a standard 5 year warranty against heat damage as well as 5 years on the gas control unit against any malfunction Warranty will only apply if installed correct...

Page 12: ...1 View of burner tray filled with white pebble stones arranged in rows on top of bed of vermiculite chips FIGURE 2 View of control knob flame size indicator FIGURE 3 View of ventilation grill supplied...

Reviews: