background image

7095-819

 1

Quadrafire  •  Expedition II AU Owner’s Manual_Rev B  •  2020 - ___  •  03/21

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation.

OWNER: Retain this manual for future reference.

Contact your dealer with questions on installation, operation, or service.

EXPEDITION II AUSTRALIAN 

WOOD INSERT

AUTOMATIC COMBUSTION 

CONTROL (ACC)

MODEL NUMBER:

EXPEDITIONII-AU

®

• 

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

• 

Do not over fire - If appliance or chimney connector 

glows,  you  are  over  firing.  Over  firing  will  void 

your warranty.

• 

Comply with all minimum clearances to combustibles 

as specified.

Failure to comply may cause house fire.

If the information in these instructions is 

not  followed  exactly,  a  fire  could  result 

causing property damage, personal 

injury, or death.

WARNING

!

HOT SURFACES!

Glass and other surfaces are hot during 

operation AND cool down.

WARNING

!

Hot glass and appliance will cause burns.

• 

Do not touch glass until it is cooled

• 

Use leather gloves when reloading fuel

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY  SUPERVISE  children  in  same  room 

as appliance.

• 

Alert  children  and  adults  to  hazards  of 

high temperatures

•  High temperatures may ignite clothing or other 

flammable materials.

• 

Keep  clothing,  furniture,  draperies  and  other 

flammable materials away.

Fire Risk.

For use with solid wood fuel only.

Other  fuels  may  over  fire  and  generate 

poisonous gases (i.e. carbon monoxide).

WARNING

!

NOTICE: DO NOT DISCARD THIS MANUAL

Summary of Contents for EXPEDITIONII-AU

Page 1: ...ibles as specified Failure to comply may cause house fire If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING...

Page 2: ...been TESTED TO AS NZS 4012 13 for Hardwood by ASFT Report ASFT20046 Date tested MAY 2020 EXPEDITIONII AU WOOD INSERT R OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD WHEN TESTED IN ACCORDANCE TO AS NZS 4...

Page 3: ...ons 15 3 Maintenance and Service A Quick Reference Maintenance Guide 16 B General Maintenance 17 C Correct Baffle Blanket Placement 19 4 Troubleshooting Guide 20 5 Service Parts Replacement A Glass 21...

Page 4: ...nufacture After installation if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period HHT will at its option repair or repl...

Page 5: ...occur This is not a flaw and is not covered under warranty Damage to printed plated or enamelled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and...

Page 6: ...o improper chimney or venting installation HOW TO CLAIM To make a claim against this warranty contact your local distributor during regular business hours See addresses below for a dealer nearest you...

Page 7: ...ces of Dry Split Wood The appliance is ready for normal operation Warning Risk of Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke fla...

Page 8: ...mbling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a...

Page 9: ...hildren in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keepclothing furniture draperiesandotherf...

Page 10: ...n absorb water from rain or snow delaying the seasoning process B Fire Safety To provide reasonable fire safety the following should be given serious consideration 1 Install at least one smoke detecto...

Page 11: ...h burn setting for a longer time to start it burning The heat generated from the fire should be warming your home and establishing the flue draft not evaporating the moisture out of wet unseasoned woo...

Page 12: ...f the firewood you use Seasoned wood contains about 8 000 BTUs per pound Hard woods are more dense than soft woods Hard woods contain 60 more BTUs than soft woods Hard woods require more time to seaso...

Page 13: ...ivens up the coal bed and reduces excessive emissions opacity smoke Open door slowly so that ash or smoke does not exit appliance through opening Large logs burn slowly holding a fire longer Small log...

Page 14: ...utomatically and is controlled by the internal snap disc MANUAL Overrides the internal snap disc AUTO Fan will turn ON OFF automatically and is controlled by the internal snap disc 2 The blower is equ...

Page 15: ...pressure can cause spillage of combustion fumes soot and carbon monoxide Appliance needs to draft properly for safety WARNING Do NOT operate a circulating fan within close proximity approximately 4 ft...

Page 16: ...acked or broken Door Glass Assemblies WEEKLY or after every 25 loads of wood Keep door and glass gasket in good shape to maintain good burn To test place a dollar bill between the appliance and door a...

Page 17: ...estroy the house The chimney connector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has acc...

Page 18: ...er Abrasive cleaners may scratch and cause glass to crack If the deposits on the glass are not very heavy normal glass cleaners work well Heavier deposits may be removed by using a damp cloth dipped i...

Page 19: ...le Board MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket The baffle boards are FRAGILE Use ex...

Page 20: ...r to Minimum Height of Flue System Exit on page 12 of Installation Manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Fuel...

Page 21: ...inges 4 Lay door face down on a table or counter making sure the handle hangs over the edge so the door lays flat on a soft surface 5 Remove the screws from each glass retainer and remove the glass If...

Page 22: ...the hold down bracket into the placement slot D Snap Disc Service Part SRV230 0470 1 Ensure that the fire is out and the appliance is cool to the touch 2 Remove the door by lifting the door up and of...

Page 23: ...and the right side lowered Follow steps 1 through 4 on page 24 for removal of the tube channel assembly It is not necessary to completely remove the tube channel assembly 3 Once the baffle protection...

Page 24: ...ing to remove them 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back to right Figure 5 12 5 The ceramic blanket an...

Page 25: ...7095 819 25 Quadrafire Expedition II AU Owner s Manual_Rev B 2020 ___ 03 21 Date of Service Performed By Description of Service A Service Maintenance Log 6 6 Reference Materials...

Page 26: ...7095 819 26 Quadrafire Expedition II AU Owner s Manual_Rev B 2020 ___ 03 21 Date of Service Performed By Description of Service...

Page 27: ...___ 03 21 B Service Parts Service Parts R EXPEDITIONII AU Beginning Manufacturing Date Sept 2020 Ending Manufacturing Date Active Cast Iron Wood Insert Large Part number list on following page 08 20...

Page 28: ...V7095 119 Y 8 Tube Support Rack SRV7095 124 Screw Hwh Ms 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y 9 Tube Channel Assembly SRV7095 016 Screw Hwh Ms 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y Nut Flange 1 4...

Page 29: ...h Tx 1 4 20 x 1 7000 622 10 Y 13 Door Assembly SRV7095 053 13 1 Door SRV7095 205 13 2 Glass Assembly SRV7095 054 13 3 Glass Retainers Qty 4 req SRV7063 166 Screw Pan Head Phillips 8 32 x 3 8 Pkg of 40...

Page 30: ...sting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 16 Fascia Assembly SRV7095 057 16 1 Front Trim Upper w Screen SRV7095 209 Screw Pan Head phil...

Page 31: ...SRV7095 033 18 1 Speed Control SRV7000 731 Y 18 2 Knob Speed Control 200 2041 Y 18 3 Rocker Switch Round SRV7000 940 Y 19 Power Cord SRV7000 636 Y 20 Wire Harness SRV7095 158 Y 21 Snap Disc 1 Convecti...

Page 32: ...PART NUMBER 24 Combustion Cover SRV7095 134 Hurricane Screw Pkg of 40 SRV2005 861 40 Y 25 Convection Side Panel SRV7095 166 Component Pack SRV7095 070 Surround 43 x 31 SP2 4331 Surround Trim Assembly...

Page 33: ...f 25 220 0080 25 Bolt 5 16 x 18 x 1 Pkg of 12 27887 12 Y Nut 5 16 18 Pkg of 10 A 3483 1 10 Y Nut flange 1 4 20 Pkg of 24 226 0130 24 Y Screw FH HX 1 4 20 x 1 Pkg of 6 7000 622 6 Y Screw 10 32 x 75 HWH...

Page 34: ...UAL Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and ope...

Reviews: