background image

D

P

MP

N

C

P

D

PO

T U

S V D U J P O D

PS

Q

P

S

B

U

J

P

O

/

OFX ZPSL

/

D!

P!

M!P!

N!

C!

P!

D!

P!O!

T!U!

S!V!D!U!J!P!O! D!

P!S!

Q!

P!

S!

B!

U!

J!

P!

O!

/!

O!F!X! Z!P!S!L!

/!

COLOMBO CONSTRUCTION CORP

342 Park AVE Brooklyn, NY 11205

T  718.399.2233  F  718.399.2237  M 212.334.5069

firefeatures.com

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS & LIQUIDS IN THE VICINITY OF 
THIS OR ANY OTHER APPLIANCE. 

WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property 

damage, personal injury or loss of life.

DO NOT DISCARD THIS MANUAL

• Important operating and maintenance instructions included. 
• Read, understand and follow these instructions for safe installation and operation.
• Leave this manual with party responsible for use and operation.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. 
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.

INSTALLATION & SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY 

OR GAS SUPPLIER.

WARNING:

 Improper installation, adjustment, alteration, service or maintenance can cause in-

jury or property damage. Read the installation, operating and maintenance instructions thoroughly 
before installing or servicing this equipment.

WARNING: FOR OUTDOOR USE ONLY

REMOTE MANUAL PILOT IGNITION

54NL BASE MOUNTED FIREBOWL

Summary of Contents for 54NL

Page 1: ...d follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Page 2: ......

Page 3: ...EBOWL 4 5 7 9 10 11 12 13 16 17 18 19 20 Technical Quick View Warnings Overview Burner and Pilot Assembly Venturi Orifice Components Control Panel Ignition Shut off Emergency Shut Off Lava rock Maintenance Replacement Parts TABLE OF CONTENTS 3 CONTENTS ...

Page 4: ...VALVE COUNTERCLOCKWISE TO THE ON POSITION 3 TURN FLAME HEIGHT VALVE COUNTERCLOCKWISE TO LOW POSITION 4 LOCATE PILOT ASSEMBLY ON MAIN BURNER 5 PUSH RED BUTTON FOR PILOT HOLD 6 IMMEDIATELY IGNITE PILOT WITH EXTENDED TORCH CONTINUE TO HOLD RED PILOT BUTTON DOWN FOR AT LEAST 30 SECONDS UNTIL PILOT STAYS LIT 7 RELEASE PILOT BUTTON REMOVE EXTENDED TORCH FROM PILOT ASSEMBLY MAKE SURE PILOT STAYS LIT 8 SL...

Page 5: ...ter More frequent cleaning may be required as necessary It is im perative that control compartment burners and circulating air passageways of the appliance be kept clean to provide for ad equate combustion and ventilation air This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases The appliance and its individual ...

Page 6: ...sturbed when installing including but not limited to the valve train must be leak test ed by a certified gas technician prior to use LEAK TESTING PROCEDURE Perform a leak test at least once each year whether the gas supply has been disconnected or not Conduct a leak test anytime the gas supply is connected to the regulator or any part of the gas system is disconnected or replaced As a safety preca...

Page 7: ...REMOTE MANUAL PILOT IGNITION 54NL BASE MOUNTED FIREBOWL OVERVIEW FIRE FEATURE 7 ...

Page 8: ...OT HIDDEN EACH APPLIANCE IS SUPPLIED WITH A GAS REGULATOR AND IT SHOULD BE INSTALLED WITH IN 10 15 FEET OF THE APPLIANCE 3 4 GAS LINE CONNECTION IN SECTION A SECURE BOWL THROUGH THE CENTER HOLE OF THE BOWL 3 8 HARDWARE 16 14 2 SECTION B PILOT BURNER AND THERMOCOUPLE 4 20 54 DIA 54NL FIREBOWL PILOT BURNER AND THERMOCOUPLE DISTANCE BETWEEN PILOT ASSEMBLY AND PUSH FOR PILOT CAN BE NO GREATER THAN 36 ...

Page 9: ...REMOTE MANUAL PILOT IGNITION 54NL BASE MOUNTED FIREBOWL BURNER AND PILOT ASSEMBLY PART COMPONENTS LEGEND 1 Pilot Guard 2 Baso Thermocouple K16RM 180H 3 Baso Pilot Assembly J992MDA 2 4 Main Burner 9 ...

Page 10: ... positioning keeps the flame looking yellow and natural The more oxygen you let in the smaller and bluer the flame If the oxygen is shut off completely the flame will contain more soot and unburned contaminents You may adjust the Venturi according to visual preference 10 1 2 3 LEGEND Brass Orifice Venturi Adjustable Air Shutter 90M Stainless Steel Venturi Air Mixer ...

Page 11: ...ed by calling Colombo Construction Corp 718 399 2233 or 212 334 5069 or by emailing info firefeatures com LEGEND Lid Lighting Instructions Gas Line To Burner Flame Height Control Valve Thermocouple Line Press for Pilot Button On Off Gas Valve Gas Line In Pilot Gas Line Control Panel Back Plate Control Panel 1 2 3 4 5 6 7 8 9 10 ...

Page 12: ...MANUAL PILOT IGNITION 54NL BASE MOUNTED FIREBOWL IN THE OFF POSITION LEGEND 3 4 Ball Valve Flame adjustment Pilot Button H15DA 3C Baso Safety Valve 3 4 Gas Ball Valve On Off 1 2 3 CONTROL PANEL 12 Off Position ...

Page 13: ...e at arms length Do not lean over the appliance Use safety goggles and a extended torch Make sure gas valve and flame height valve are in the OFF position Turn gas valve counterclockwise to the ON position Locate pilot assembly on main burner IGNITION CONTINUES ON THE NEXT PAGE A B C A B C ...

Page 14: ...ockwise to LOW position Immediately ignite pilot with extended torch continue to hold red pilot button down for at least 30 seconds until pilot stays lit Release pilot button remove extended torch from pilot assembly and make sure pilot stays lit Slowly turn flame height valve counterclock wise to HIGH position Adjust flame height to preference IGNITION CONTINUES ON THE NEXT PAGE IGNITION D E F D ...

Page 15: ...GNITION 54NL BASE MOUNTED FIREBOWL 15 IGNITION SUCCESSFUL IGNITION If main burner does not light or you smell or hear gas immediately turn gas valve flame height valve to off position Wait 5 minutes and repeat steps B to F ...

Page 16: ...urn gas valve clockwise to OFF position Wait for gas to burn out of line Wait for burner to fully extinguish Turn flame height valve clockwise to OFF position Always shut down gas valve first flame height valve second To re light burner wait 5 minutes after a complete shut off A A B C B C ...

Page 17: ...PILOT IGNITION 54NL BASE MOUNTED FIREBOWL EMERGENCY SHUT OFF PLAIN VIEW SHUT OFF TO PUT BURNER OUT In the event of a uncontrolled fire always be aware of where the emergency shut off valve is located OFF POSITION 17 ...

Page 18: ...ze to use with your firebowl You will need approxi mately 100 to 200lbs for the firebowls Please contact the following website to or der lava rocks if you are unable to find any at your local garden supply store http www fountainsnslate com 1 800 643 5804 or 1 386 586 4062 WARNING Other rocks may contain water and when heated will split crack or burst and are therefore to be used at your own risk ...

Page 19: ... is on and while main burner is off Replace any cor roded parts Be certain that pilot position is correct and that pilot reliably and accurately ignites main burner Use a tooth pick or thin wire to poke out any clog or obstruction from the small holes in the burner only when the burner is off Check to be certain that the area the gas equipment operates in is free of obstruction Remember that for p...

Page 20: ...ASSEMBLY 6 Baso Pilot Assembly J992MDA 2 7 Baso Brass Pilot Orifce Assembly Includes NG or LP Orifice 8 1 4 O D Pilot Light Feed Tubing 9 Baso Thermocouple K16BA 60 MAIN BURNER ASSEMBLY 10 Main Burner 11 Stainless Steel Venturi Air Mixer 12 Stainless Steel Air Shutter 13 Brass Orifce Assembly REPLACEMENT PARTS 20 All parts may be ordered by calling Colombo Construction Corporation 212 334 5069 or ...

Page 21: ......

Reviews: