- 2 -
1. ORDERING GUIDE
Configure a model number in this format:
L20201DCV1, CBL01
L
…Digital panel meter with
screw terminal connectors.
Display Color
1
............. DPM with green LED
2
................. DPM with red LED
3
.... Extended DPM, green LED
4
........ Extended DPM, red LED
Note:
Extended adds rate of
change & linearization of non-
linear inputs. Not applicable to
thermocouple or RTD inputs.
Power
0
..... 85-264 Vac or 90-300 Vdc
1
......... 10-48 Vdc or 12-32 Vac
Setpoint Output
0
...................................... None
1
............ Two 8A contact relays
2
............ Two solid state relays
3
........... Four 8A contact relays
4
............ Four solid state relays
Analog Output
0
...................................... None
1
..... 4-20 mA, 0-10V, -10/+10V
Digital Interface
0
...................................... None
1
.................................... RS232
2
.................................... RS485
4
...................... RS485-Modbus
5
....................................... USB
6
......... USB-to-RS485 gateway
7
................................. Ethernet
8
... Ethernet-to-RS485 gateway
Input Type
DC Volts
DCV1
..................... 200.00 mV
DCV2
........................ 2.0000 V
DCV3
........................ 20.000 V
DCV4
........................ 200.00 V
DCV5*
......................... 600.0 V
DCV6
.......................... 300.0 V
DC Amperes
DCA1
.................... 2.0000 mA
DCA2
.................... 20.000 mA
DCA3
.................... 200.00 mA
DCA4
......................... 5.000 A
RTDs
P385C
.. Pt100, -202 to 850°C
P385F
..Pt100, -331 to 1562°F
P392C
. . Pt100, -202 to 850°C
P392F
..Pt100, -331 to 1562°F
N672C
. ... Ni120, -80 to 260°C
N672F
... Ni120, -112 to 500°F
C427C
. .... Cu10, -97 to 260°C
C427F
.... Cu10, -143 to 500°F
Thermocouples
JC
.................... -210 to 760°C
JF
................... -347 to 1400°F
KC
................. -244 to 1372°C
KF
................... -408 to 2501°F
TC
.................... -257 to 400°C
TF
..................... -430 to 752°F
EC
................. -240 to 1000°C
EF
................... -400 to 1830°F
NC
................. -245 to 1300°C
NF
................... -410 to 2370°F
SC
................... -46 to 1768°C
SF
..................... -51 to 3214°F
RC
................... -45 to 1768°C
RF
..................... -49 to 3213°F
Resistance / Ohms
R0
....... 0-2 ohms (fixed range)
R1
...................0-20.000 ohms
R2
...................0-200.00 ohms
R3
................. 0-2.0000 kohms
R4
................. 0-20.000 kohms
R5
................. 0-200.00 kohms
R6
.... 0-2 Mohms (fixed range)
Process Signals
(4-20 mA, 0-10V, etc.)
P
............. 4-20 mA = 0-100.00
P1
……………Custom Scaling
Specify min signal & reading,
max signal & reading.
RMS Volts
RMV1
.................... 200.00 mV
RMV2
....................... 2.0000 V
RMV3
....................... 20.000 V
RMV4
....................... 200.00 V
RMV5*
....................... 600.0 V
RMV6
......................... 300.0 V
RMS Amperes
RMA1
.................... 2.0000 mA
RMA2
.................... 20.000 mA
RMA3
.................... 200.00 mA
RMA4
......................... 5.000 A
Load Cells
(6-wire ratio)
WM1
….….-99,999 to +99,999
Specify min input signal & dis-
played reading, and max input
signal & displayed reading.
Full-scale inputs 20.000 mV to
500.00
mV, 10 Vdc excitation.
Options & Accessories
BL
......... Blank lens, no
button pads
.
CBL01
.. RJ11-to-DB9 RS232
cable. Connects me-
ter to PC com port.
CBL02
.. USB-to-DB9 adap-
ter. For use with
CBL01.
CBL05
.. USB-cable. Type A
male to Type B
male.
IPC
........ NEMA-4 panel
cover.
BOX1
.... NEMA4 wall mount
enclosure.
BOX2
.... BOX1 plus IPC.
CASE1
.. Benchtop case for 1
meter.
CASE2
.. Benchtop case for 2
meters.
* Range not ETL certified