LaserBit Giga Series 4.3 page
33
5
Hands tighten the two bolts.
6
Tight the front bolt with a 10mm spanner and look at the readings on the
receiver, if the receiving level start decreasing again, start using the bolt
on the rear and tighten it with the spanner, and reach the maximum again.
We strongly suggest you to repeat the steps 2-3 times to make sure that
the bolts are tight
•
Repeat the steps 1-6 on the remote end as well.
•
Now the system is secured with the fine adjustment bolts. The long term
alignment bolts should be tightened on side and on the button of the unit.
/Please note: During the tightening process should you experience some
movements. This should be compensated with further tightening of the fine
adjustment bolts./
10.2.4
Connecting to your Network
You have a TC head
You can find a two sided fibre connector
in your ODIU. You have to connect the
fibre cable of your head into the one
side of the connector, and into the other
side you have connect the fibre cable of
you network equipment (switch; router
or LB combiner). The fibre plugs of the
heads are always SC typed, which
means that them cross-sections are
cubic form. The fibre connector in the
ODIU is SC-SC typed, so you have to
provide an SC fibre plug for you network. The SC-SC connector is a reversible part,
so you can connect in the first plug where you want, the important is that the two
plugs of the head have to be on one side, and the two plugs of the network have to
be on the other, and if you plug in the transmitter side of the head into a connector,
then the transmitter side of the network have to be in the opposite connector of the
previous, and do the same with the other sides too.