LaserBit Giga Series 4.3 page
41
10.4 GigaPRONTO systems
10.4.1
How can you install the ODIU?
Functionalities of the ODIU
The outdoor interconnection unit (ODIU) provides the power supply and data
connection for the head. The power connection (+12VDC, GND, -12VDC).
The ODIU made from poly-propylene enforced with fibre. This construction provides
robust shock and waterproof environment (IP65) for the electrical devices.
The transformer is a not switch able transformer, so the main voltage must match to
the one marked on the front cover. If the main power is different then this can
damage the transformer.
In the ODIU there can be found four fuses, two for the transformer and the other two
for the head.
Fuses
On the primarily side, the fuse ratings are: T1,6A (250V)
- in the case of glassheater the fuses are T1,6A (250V)
On the secondary side, the fuse ratings are: T8A (250V)
- in the case of glassheater the fuses are T8A (250V)
On the glassheater-panel the fuses are T6,3A (250V)