Services
E220 Series Cellular Router User Guide
207
Events
Services > Events
E200 and E220 Router is equipped with two digital inputs/outputs (I/O). Digital inputs range is 3V to
24V and the same input pins are also available to be used as open collector digital output with maximum
200mA @ 24V. Event page allows you to mapping actions to events respective to digital I/O’s.
Screen 11-8: Event Service Configuration
Parameters
Description
EVENT
Enable
Click to enable the events
Event
Select the event from the available options
•
DIO_H – High voltage state on DI
•
DIO_L – Low voltage state on DI
DIO is by default are pulled up to high voltage level.
Action
Select the action from options.
•
SMS – to send the event details using the SMS.
•
Switch Digital Output – Change the state of Digital Output
•
Reboot – To reboot the router.
Mobile Number
Enter the mobile number. The mobile number format must be:
<countrycode><phonenumber>
Text
Enter the text message that will be sent to the configured mobile
number in case of event occurs.
Table 11.9-1: Event Service Configuration