15: Maintenance
EMG™ Edge Management Gateway User Guide
355
3. You have the following options:
-
To add the defined event, click the
Add Event
button. The event displays in the Events
table at the bottom of the page.
-
To edit an event, select the event from the Events table and click the
Edit Event
button.
-
To delete an event, select the event from the Events table and click the
Delete Event
button. A message asks for confirmation. Click
OK
.
4. To save, click
Apply
.
Outlet
When the trigger is set to
RPM Load over Threshold
, select the outlet that will be
monitored for a current that exceeds a defined threshold. The RPM needs to
support providing a current level for the selected outlet as part of its status
information. If an outlet is not specified, the current level for the entire device will be
monitored. The RPM current will be checked every 2 minutes.
Threshold
When the trigger is set to
RPM Load over Threshold
, specify the maximum
allowable threshold for the current; any current readings over this threshold will
trigger the selected action. The threshold can be specified in Amps (e.g. 8.5) or as
a percentage (e.g. 90%).
DIO Port
When the trigger is set to
DIO Port State Change
or
DIO Port State Abnormal
,
select the DIO port to monitor. For state change, the selected action will be
triggered if the state changes from On to Off or from Off to On. For state abnormal,
the selected action will be triggered if the state changes from the
Normal
state to
the opposite state (see
Action
From the drop-down list, select the action taken because of the trigger. For
example, the action can be writing an entry into the syslog with details of the event
or sending the trap(s) to the Ethernet or modem connection.
Syslog
Forward All Traps to Ethernet
Forward Selected Trap to Ethernet
Forward all Traps to a Modem Connection
Forward Selected Trap to a Modem Connection
Email Alert
SNMP Trap
Turn DIO Relay On
Ethernet
For actions that require an Ethernet connection (for example,
Forward All Traps to
Ethernet
), select the Ethernet port to use.
Modem Connection
on
For actions that require a modem connection (for example,
Forward All Traps to a
Modem Connection
, select which modem connection to use (
Device Port
,
USB
Port U1
, or the
Internal Modem
).
NMS/Host to forward
trap to
For actions that forward a trap, enter the IP address of the computer to forward the
trap to. The computer does not have to be an SNMP NMS; it just has to be capable
of receiving SNMP traps.
SNMP Community
Forwarded traps are sent with this SNMP community value
There is no default.
SNMP Trap OID
Enter a unique identifier for an SNMP object. (An SNMP object is anything that can
hold a value and can be read using an SNMP "get" action.) The OID consists of a
string of numbers separated by periods (for example, 1.1.3.2.1). Each number is
part of a group represented by the number on its left.
Email Addresses
Enter an email address to receive email alerts.
Summary of Contents for EMG Series
Page 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings...
Page 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG...
Page 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity...
Page 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued...