Error location parameter number!
The
go
command you entered had an invalid or missing parameter.
1. Enter the
go
command with all of the location parameters (chassis / slot / port) in the format:
go [c=CHASSIS] [s=
SLOT
] [l1ap=
PORT
] [l2ap=
PORT
] (l1p=
PORT
|l2p=
PORT
|l3p=
PORT
|l1d|l2d|l3d)
Fail to set link pass through state!
You tried to set the LPT state to an unacceptable state. For example, you typed:
C1|S3|L1D>
set lpt state=enable
and then pressed
Enter
.
1. Verify the CLI command syntax.
2. Check the
set lpt monitor-port
and
set selective lpt state
command settings.
3. Enter the
show lpt config
command and in the Link Pass Through configuration, check if the Link
pass through state is set to
notSupported
or if the
Remote fault detect state
is set to
notSupported
.
If either is set to
notSupported
, change the setting to enable (e.g., type
set rfd state enable
and
press
Enter
).
4. Retry the operation.
5. For a complete list of the available commands, see the
x4120 CLI Reference Manual, 33497.
6. If the problem persists, contact Technical Support.
TFTP transfer failed!
1. The attempted firmware upgrade via the
tftp upgrade
command was unsuccessful.
2. Verify the CLI command syntax.
3. Verify the firmware version.
4. Be sure the TFTP server is configured and running.
5. Check that the remotefile is in the proper location (e.g., the file
x222x / x32xx.bin.0.5.4
is at
C:\TFTP-
Root
).
6. Retry the operation. See the
tftp upgrade
command in the
x4120 CLI Reference Manual, 33497.
7. If the problem persists, contact Technical Support.