12
Power On
Connect the 3-prong AC power cord or the 14-pin 2-row DC power cable to the power
socket at the rear panel of the Ethernet switch. The Ethernet switch can work with AC
power in the voltage range of 100-240V/50~60Hz or 12-48VDC. The AC and DC inputs
can be used for redundant power supply. If one of the power inputs fails, the other one
is able to keep providing power to the Ethernet switch. Check the power LED indicator
on the front panel to see if power is properly supplied.
Redundant power
Connect the optional redundant power cord to the redundant power socket on the rear
panel of the Switch. The other side of redundant power cord connects to the power
supply. The Switch works with power supply of 12-48 VDC.
Please make sure the connection on power supply is correct when using the optional
redundant power cord. Red cord should be co
nnected to ―+‖ and black cord should be
connect to ―-‖.