12
8. With the graduated cylinder placed in a position below the
nozzle, press the Start Purge button. The unit will dispense
the volume designated in the previous step.
9. Examine the dispensed volume in the graduated cylinder. If
the dispensed volume does not match the value entered on
the screen in step 7, use a screwdriver to adjust the
carbonated water flow control. (See Plumbing Diagram on
page 17 for reference).
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
10.
Repeat steps 8 and 9 if any more bonus flavor flow
adjustment is necessary.
11.
Repeat steps 4 - 10 for any remaining bonus flavor module.
12.
To re-attach the screen housing, first align the screen
housing with the connection tabs on the unit, then rotate the
housing down untill the connection tabs engage.
13.
Re-connect the two thumb screws removed in Step 2.
14.
Repeat steps 1 -13 for the second screen.
Make sure both of the connection tabs are disengaged
in the open position before attempting to re-connect
the screen housing. Use a screw driver to open the
connection tabs if necessary.
NOTE
FEATURES OF THE FS44 SENSATION
System Settings
1. From the Service menu, press the
System
button.
2. Press the
Enabled
button, below the “Enable Water
Dispenses” heading, to have the ability to pour plain/
carbonated water from the main screen.
3. Press the
Enabled
button, below the “Enable Flavor Shots”
heading, to have the ability to pour flavor shots from the
main screen.
4. Press the
Enabled
button, below the “Show Nutrition”
heading, to have the ability to display a selected brands
nutrition information (if available).
5. When enabled, press and hold the
Info
button from a
selected brands pour screen to display the nutrition
information.