10
7.
Using the keypad, enter a specific volume to be dispensed
based on the size of the graduated cylinder being used to
calibrate the plain water module.
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
10. Repeat steps 8 and 9 until the designated volume is
achieved.
11.
Repeat steps 5 - 10 for the carbonated water module.
12.
To re-attach the screen housing, first align the screen
housing with the connection tabs on the unit, then rotate the
housing down untill the connection tabs engage.
The larger the volume dispensed, the more accurate
the results.
NOTE
Make sure both of the connection tabs are disengaged
in the open position before attempting to re-connect
the screen housing. Use a screw driver to open the
connection tabs if necessary.
NOTE
8. With a graduated cylinder placed in a position below the
nozzle, press the
Start Purge
button. The unit will dispense
the volume designated in the previous step.
9. Examine the dispensed volume in the graduated cylinder. If
the dispensed volume does not match the value entered on
the screen in step 7, use a screwdriver to adjust the
plain water flow control. (See Plumbing Diagram on
for reference).
1. From the Service menu, press the
Maintenance
button.
2. Remove the two thumb screws connecting the plastic screen
housing to the unit (See page 9).
3. While holding the plastic screen housing, tilt the housing
forward until the housing disengages from the unit (See
page 9).
4. While holding the screen housing, press the
Calibrate
tab on
the far left side of the screen and press the
Calibrate
button
for the first brand syrup module.
The water flow rate should be set from the calibration
of the carbonated/plain water modules in the previous
section and the ratio should be determined from when
the brand was configured. (See page 8, Adding New
Brand/Flavor Module)
NOTE
Calibrating Brand Syrup Modules
5.
Using the keypad, enter a water flow rate value of 1.25 oz/
sec.
6. Set the Timer to the ON position and select ounces (oz) as
the desired unit of measurement.
4. While holding the screen housing, press the
Calibrate
tab on
the far left side of the screen and press the
Calibrate
button
for the plain water module.
13.
Re-connect the two thumb screws removed in Step 2.
14.
Repeat steps 1 -13 for the second screen.
A
A
A. Clip in Open Position
Ensure there is ice on the cold plate and the lines are
cold before attempting to set the flow rates on the
valves. The drink temperature should be no higher
than 40°F (4.4°C) when flow rates are set.
NOTE