Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
Pouring hot water into drain may cause the Drain Tube
to collapse. Allow only luke warm or cold water to enter
Drain Tube.
Pouring coffee tea and similar substances
into drain may cause the Drain Tube to become
clogged with coffee or tea grounds, or other solid
particles.
!
ATTENTION
16. Re-install cup rest and splash plate.
17. Turn on water supply and check for leaks.
18. Plug power cord into designated grounded electrical outlet.
The dispenser must be properly electrically ground-
ed to avoid serious injury or fatal electrical shock.
The power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow
all local electrical codes when making connections.
Each dispenser must have a separate electrical circuit.
Do not use extension cords. Do not connect multiple
electrical devices on the same outlet.
!
WARNING
19. Turn on the power switch, at the top of the unit, to turn on
the unit and begin building an ice bank.
Installing Remote Syrup Pumps - Bag in Box
A
B
C
A. Syrup Pump
B. CO2 Line
C. Fitting
D. Oetiker Pliers
D
1. Install BIB rack and remote pumps according to
manufacturers’ instructions.
2. Once pumps and BIB rack are installed, measure and cut
tubing to length between the pump CO
2
inlets, then connect
tubing to all pumps.
3. Using tubing cutters, cut any pump CO
2
supply line and
install tee fitting, then route appropriate tubing from the CO
2
supply to the tee fitting at syrup pumps.
A
B
C
A. Syrup Pump Outlet
B. Syrup Pump
C. Fitting
4. Connect tubing from dispenser syrup inlet to the syrup
pump outlet fitting. Repeat for each syrup line/pump.
Use proper connector for syrup manufacturer
!
ATTENTION
A. Syrup Pump Inlet C. BIB Connector
B. Fitting
D. Oetiker Pliers
A
B
C
D
A. Tee Fitting
B. Line to Syrup Pump
C. Fitting
D. Line to CO
2
Supply
A
B
B
C
D
5. Install BIB (bag in box) connectors onto the syrup pump
inlet tubing.
6. Connect syrup BIBs to connectors. Repeat for each syrup
line/pump.
14.
Route proper drain line from the designated floor drain
through the counter cutout and drip tray opening.
15.
Connect drain tube to the drain fitting located on the
bottom of the drip tray and secure drain tube with clamp.