14
TROUBLE
CAUSE
REMEDY
Water only dispensed; no
syrup; or syrup only dispensed,
no water
1.
Water or syrup shutoff on mounting block
not fully open.
2.
Improper or inadequate water or syrup
flow.
3. BIB supply too far from dispenser.
4. CO
2
pressure too low.
5. Stalled or inoperative BIB pump
6. Kinked line.
1.
Open shutoff fully.
2. Remove valve from mounting block, open
shutoffs slightly and check water and
syrup flow. If no flow, check dispenser for
freeze-up or other problems. Ensure BIB
connection is engaged.
3. Check that BIB supply is within six (6) feet
of the dispenser.
4. Check the CO
2
pressure to the pump man-
ifold to ensure it is between 70 and 80 PSI
(0.483 and 0.552 MPA).
5. Check CO
2
pressure and/or replace pump.
6. Remove kink or replace line.
No water just syrup, (Ice bank
grew to water inlet line to
carbonator tank.)
1. Low water bath level.
2. Unit not level.
3. Syrup in water bath.
4. Water cage is out of position.
5. Refrigerant leak.
6. Check water supply.
7. Carbonator timed out.
8. PCB malfunctioning.
1.
Add water until it flows from overflow tube.
2. Level unit and add water.
3.
Melt ice bank. Remove all water. Refill.
Locate possible syrup leak area and repair.
4. Reposition water cage.
5. Find leak and recharge unit. (If unit is not
frozen.)
6. Turn water ON and shut unit OFF,
7. Turn unit OFF then ON to reset
8. See page 18.
Valve will not shut off.
1. Cup lever may be sticking or binding.
2. Switch not actuating freely.
3. Solenoid armature not returning to bottom
position.
1. Correct or replace lever.
2. Check switch for free actuation.
3. Replace defective armature or spring.
Syrup only dispensed. No
water, but CO
2
gas dispensed
with syrup.
1.
Improper water flow to dispenser.
2. Carbonator pump motor has timed out.
3.
Liquid level probe not connected properly
to PCB.
4. Faulty PCB assembly.
5.
Faulty liquid level probe.
6. Water bath frozen.
7. Water line frozen.
1.
Check for water flow to dispenser (see
Insufficient Water Flow on previous page).
2. Reset by turning the unit OFF and then
3. ON (by using the ON/OFF switch on top of
the unit or unplugging unit momentarily).
4.
Check connections of liquid level probe to
PCB assembly.
5. Replace PCB assembly.
6.
Replace liquid level probe.
7. Thaw water bath and repair faulty
component. (See refrigeration related
symptoms.)
8. Refer to “Compressor starts and continues
to run until freeze and will not cut off” in
Troubleshooting.