Installing an Icemaker (if necessary)

When installing an icemaker on the dispenser, use a 

bin thermostat to control the ice level (see below). This 

will prevent damage to the dispensing mechanism. The 

bracket for mounting a thermostat is located in the ice 

bin. During the automatic agitation cycle and while    

dispensing ice, ensure there is adequate space be-

tween the top of the ice level and the bottom of the 

icemaker so the ice can move without obstruction. 

Contact your icemaker manufacturer for information  

on a suitable bin thermostat.

ATTENTION

1.  Install the icemaker per manufacturer specifications. Points 

of consideration include drainage, ventilation, and drop 

zones.

2.  An adapter plate is required when installing an icemaker. 

Contact your Sales Representative or Lancer Customer 

Service for more information.

3.  A bin thermostat is required in order to control the level of ice 

in the dispenser (Refer to ATTENTION above). Contact your 

icemaker manufacturer to obtain the correct bin thermostat. 

Failure to use an ice bin thermostat will not only void 

your IBD’s warranty but will result in the inability to 

control the level of ice in the ice bin which can cause 

damage to your dispenser.

ATTENTION

4”

Attach Bin Stat Bracket As Shown

Recommended Bin Stat Attachment

Bulb

Tube

5.  Ensure the icemaker is installed properly to allow for removal 

of the Merchandiser.

6.  Ensure manual fill is accessible.
7.  Clean and maintain icemaker per manufacturer’s                

instructions.

4.  Bin thermostat should be a minimum of 2” below the top 

edge of the dispenser. The preferred location of the bin   

thermostat is on the left side wall. 

Dispenser Installation

 

The installation, and relocation if necessary, must 

be carried out by qualified personnel with up-to-date 

knowledge and practical experience, in accordance with 

current regulations.

NOTE

1.  Remove the cup rest, drip tray, splash plate, merchandiser 

and top cover from the unit.

2.  Remove cover plate at rear of unit if not a through-the- 

counter installation.

3.  Route appropriate tubing from the water source to the plain 

water inlet at the front of the unit and connect tubing to inlet 

using the oetiker pliers and fittings,(see Plumbing Diagrams 

on page 15 for reference).

INSTALLATION

4.  Connect tubing to water source then flush water lines to 

check for leaks.

5.  Route appropriate tubing from the remote pump deck to the 

carbonated water inlet and connect tubing to inlet.

6.  Route appropriate tubing from the syrup pump location to the 

syrup inlets and connect tubing to all syrup inlets. 

7.  Route appropriate tubing from the CO

2

 source location to the 

CO

2

 inlet on the unit and connect tubing to inlet.

8.  Route the power supply cord to a grounded electrical outlet 

of the proper voltage and amperage rating.

A

B

C

A. Oetiker Pliers

B. Fitting

C. Tubing

D. Syrup/Water Inlet

D

 

DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL 

OUTLET AT THIS TIME. 

Make sure that all water lines 

are tight and unit is dry before making any electrical 

connections

WARNING

9.  Route drain hose from designated open type drain to fitting 

on Drip Tray and connect hose to fitting.

10.  Reattach Drip Tray/Cup Rest to unit.  

 

Drain line must be insulated with a closed cell 

 

insulation. Insulation must cover the entire length of 

the drain hose, including fittings. The drain should be 

installed in such a manner that water does not collect 

 

in sags or other low points, as condensation will form.

CAUTION

Summary of Contents for Bevariety ACIB Series

Page 1: ...s not a toy Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons inclu...

Page 2: ...local standards It is the responsibility of the installer to ensure compliance Water Notice Units are equipped with an automatic agitation system and will activate unexpectedly Do not place hands or f...

Page 3: ...chilled products 30 only or two chilled and one ambient product on each MVU pad Capable of dispensing flavor shots Replaces the two center LEVs Provides additional carb or non carb beverage flexibili...

Page 4: ...ack and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the remaining three sides Level unit if necessa...

Page 5: ...the left side wall Dispenser Installation The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with...

Page 6: ...ocation to the tee fitting at water line 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection installed in the previous...

Page 7: ...aking connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING A Regulator Adjustment Screw B...

Page 8: ...ctivate valve to purge syrup until steady flow is achieved 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver...

Page 9: ...press the Push button one time to change to a non carb beverage 3 Press the same brand button again to change to a carbonat ed beverage light will flash slowly 4 Press the button one more time to chan...

Page 10: ...n to capture a sample Self Serve Crew Serve 8 Verify that the syrup level is even with the water level Use screwdriver to adjust appropriate LFCV if necessary 9 Repeat steps 7 8 for each brand on MVU...

Page 11: ...save 60 seconds after all changes have been made NOTE 5 Repeat Steps 2 4 for each of the desired brands 6 Press the Pour Cancel button to save Cleaning Solution Mix a mild non abrasive detergent e g...

Page 12: ...lush solution from the dispenser Cleaning and Sanitizing Syrup Lines Figal Tank 1 Disconnect syrup inlet from the figal syrup tank 2 Prepare cleaning solution and using a plastic bristle brush scrub b...

Page 13: ...off power to the dispenser 2 Remove Merchandiser 3 Remove Ice Chute Lever then remove Splash Plate Assembly by lifting it up and out from the dispenser face 4 Remove the Ice Chute Assembly base by rem...

Page 14: ...14 WIRING DIAGRAMS ACIB 22 30...

Page 15: ...15 PLUMBING DIAGRAMS ACIB 22 30...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: