 ACIB Dispenser Numbering Convention Bevariety

TM

 ACIB Dispenser Kit Part Numbers

 

22” Dispenser:

 85-204AA-B-C-XYZ

 

30” Dispenser:

 85-218AA-B-C-XYZ

 

44” Dispenser:

 85-208AA-B-C-XYZ

 

AA = Number of flavors

 

B = Merchandiser graphics designation

 

C = MVU option: 0 - no MVU, 2 - MVU

 

X = Valve flow rate

 

Y = Valve Type

 

Z = Splash Plate Type

 

82-4004 - 4” Heavy Duty Adjustable Leg Kit (4 Legs)

 

82-4054 - 22” Drip Tray Kit

 

82-4055 - 44” Drip Tray Kit

 

82-4046 - 30” Drip Tray Kit

 

82-4007 - 44” Joining Kit, Hardee’s

 

82-3962 - 44” Joining Kit, Carl’s Jr

Unit Overview

The Bevariety™ ice combo is a multi-brand, flavor shot capable 

beverage dispenser. It has a carbonator tank integrated into the 

cold plate so it provides true, cold carbonated, sparkling 

beverages.

Above Counter Ice Combo:

•  Available in 22”, 30”, and 44” wide models.
•  22” Six Valve: Valves 1 and 6 are carb water only, Valves 2-5 

are non-carb water or carb water capable.

•  30” Eight Valve: Valves 1, 2, 7, and 8 are carb water only, 

Valves 3-6 are non-carb water or carb water capable.

•  44” model is two 22” units joined by a kit with optional 

Multi-Flavor Valve Unit (MVU).

Features of Optional Multi-Flavor Valve Unit

•  Capable of serving up to three additional brands on each 

side of the ice dispenser through the MVU valve.

•  Can dispense up to three chilled products (30” only) or two 

chilled and one ambient product on each MVU pad.

•  Capable of dispensing flavor shots.
•  Replaces the two center LEVs.
•  Provides additional carb or non-carb beverage flexibility via a 

carb/non-carb convertor located behind the backblock of the 

four center valve positions.

 

Valves 3 or 6 on a 30 inch ACIB (valves 2 or 5 on 22 inch 

ACIB) can be set to pour either carbonated or non-

 

carbonated beverages by pulling out the converter, 

 

rotating 180°, and reinserting it into the dispenser. 

 

The 30” ACIB has two more LEV’s in addition to more 

cooling capacity and a larger ice bin.

NOTE

NOTE

 

You must shut down both still and sparkling water    

supplies as well as the CO

2

 line and syrup supply to 

change out the switchable backblock.

NOTE

To change from plain to soda:

1.  Shut off water, syrup, and CO

2

.

2.  Gas-out the dispenser.
3.  Remove valve and backblock.
4.  Pry converter out with a small flathead screwdriver.
5.  Reinstall converter in correct position.

Features of Plain/Soda Water Converter 

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Numer:

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this 

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

Summary of Contents for Bevariety ACIB Series

Page 1: ...s not a toy Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons inclu...

Page 2: ...local standards It is the responsibility of the installer to ensure compliance Water Notice Units are equipped with an automatic agitation system and will activate unexpectedly Do not place hands or f...

Page 3: ...chilled products 30 only or two chilled and one ambient product on each MVU pad Capable of dispensing flavor shots Replaces the two center LEVs Provides additional carb or non carb beverage flexibili...

Page 4: ...ack and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the remaining three sides Level unit if necessa...

Page 5: ...the left side wall Dispenser Installation The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with...

Page 6: ...ocation to the tee fitting at water line 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection installed in the previous...

Page 7: ...aking connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING A Regulator Adjustment Screw B...

Page 8: ...ctivate valve to purge syrup until steady flow is achieved 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver...

Page 9: ...press the Push button one time to change to a non carb beverage 3 Press the same brand button again to change to a carbonat ed beverage light will flash slowly 4 Press the button one more time to chan...

Page 10: ...n to capture a sample Self Serve Crew Serve 8 Verify that the syrup level is even with the water level Use screwdriver to adjust appropriate LFCV if necessary 9 Repeat steps 7 8 for each brand on MVU...

Page 11: ...save 60 seconds after all changes have been made NOTE 5 Repeat Steps 2 4 for each of the desired brands 6 Press the Pour Cancel button to save Cleaning Solution Mix a mild non abrasive detergent e g...

Page 12: ...lush solution from the dispenser Cleaning and Sanitizing Syrup Lines Figal Tank 1 Disconnect syrup inlet from the figal syrup tank 2 Prepare cleaning solution and using a plastic bristle brush scrub b...

Page 13: ...off power to the dispenser 2 Remove Merchandiser 3 Remove Ice Chute Lever then remove Splash Plate Assembly by lifting it up and out from the dispenser face 4 Remove the Ice Chute Assembly base by rem...

Page 14: ...14 WIRING DIAGRAMS ACIB 22 30...

Page 15: ...15 PLUMBING DIAGRAMS ACIB 22 30...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: