8.26
BIB pump fails to restart A. BIB connector not on tight.
A. Tighten BIB connector.
after bag replacement.
B. BIB connector is stopped up.
B. Clean out or replace BIB
connector.
C. Kinks in syrup line.
C. Straighten or replace line.
8.27
BIB pump fails to stop
A. Leak in discharge line or
A. Repair or replace discharge line.
when dispensing valve
fittings.
is closed.
B. Empty BIB.
B. Replace BIB.
C. Air leak on inlet line or bag
C. Repair or replace.
connector.
8.28
Low or no carbonation.
A. Low or no CO
2
.
A. Check CO
2
supply. Adjust CO
2
pressure to 70 PSI.
B. Excessive water pressure.
B. Water regulator should be set at
50 PSI.
C. Low water pressure.
C. Must be 25 PSIG flowing with
carbonator pump running.
D. Worn or defective carbonator
D. Replace carbonator pump.
pump.
8.29
Carbonator pump not
A. Timed out.
A. Check water supply; turn machine
running.
off and on.
B. Fuse blown on PCB.
B. Replace fuse F1 on PCB.
C. Faulty carbonator probe.
C. Disconnect J14 connector from
PCB. If pump runs with probe
disconnected but will not run with
carbonator empty and probe
connected, replace probe.
D. Air in carbonator.
D. Purge carbonator (see
Section 1.14).
E. Faulty PCB.
E. Replace PCB.
NOTES
16
TROUBLE
CAUSE
REMEDY