5.2
CARB/PLAIN WATER CONFIGURATION
The following plumbing configurations are possible.
Plain water is dispensed from the left nozzle
only.
To select whether a flavor is carbonated or not, plug the respective syrup module into the
connector marked "Carb" or "PW" for that switch (SW4 or SW5, see Figure 1 and Section 9.7).
A.
Four Flavor
4-0
: All flavors are carbonated; plain water available from water button only; unused switch on
right side may be jumpered per Section 5.1;
3-1
: Two (2) flavors on right nozzle carbonated; one (1) flavor on left nozzle carbonated;
one (1) flavor on left nozzle plain water; unused switch on right side may be jumpered per
Section 5.1;
2-2
: Two (2) flavors on right nozzle carbonated; two (2) flavors on left nozzle plain water;
unused switch on right side may be jumpered per Section 5.1.
B.
Five Flavor
5-0
: All flavors are carbonated; plain water available from water button only; no jumper used;
4-1
: Three (3) flavors on right nozzle carbonated; one (1) flavor on left nozzle carbonated;
one (1) flavor on left nozzle plain water; no jumper used;
3-2
: Three (3) flavors on right nozzle carbonated; two (2) flavors on left nozzle plain water; no
jumper used.
5.3
PORTION CONTROL FEATURE
The middle column of switches selects portion control sizing when programmed (see Figure 1). The
pour size is selected by pressing and releasing the desired size first, and then the desired flavor
switch is pressed and released to start the dispense. The LED will light up until the flavor button is
pressed. Size preference is given to the last switch pressed. Pressing pour cancel at any time
deselects the size and stops the dispense. The individual flavor switches will operate manually if no
size selection is made.
A. PROGRAMMING PROCEDURE
1. To turn the Portion Control feature on, enter the programming mode by simultaneously
pressing and holding the lower two switches (Medium and Large, see Figure 1) until the
LED starts blinking, then release the switches. The LED will continue blinking while in
programming mode.
2. Put desired amount of ice in cup. Place cup under nozzle, press and release selected size
switch (Small, Medium, or Large), press and hold a flavor switch until the cup fills to the
desired level, then release the switch.
3. Wait for the foam to settle, then actuate the flavor switch again to set Top-Off.
4. Repeat Steps 2 and 3 for the other two drink sizes.
5. Repeat Steps 2, 3 and 4 for all other flavors.
6. After programming all drink sizes, press and release the Pour Cancel switch to return to the
operational mode. The LED will stop blinking.
7. To turn the Portion Control feature off, enter the programming mode (Step 5.3.A.1), and then
press and hold the Small and Medium switches until the LED stops blinking.
8. If Top-Off is not desired or required, the following steps must be followed:
a. Follow steps 5.3.A.1 and 5.3.A.2 above.
b. Repeat Step 5.3.A.2 for remaining drink sizes.
c. After actuating the last selected size switch, momentarily actuate one of the other size
switches. This will signal the microprocessor that all selected sizes are complete.
d. Repeat Step 5.3.A.6 above.
9. To change a dispense size, use the above procedure for the selected size; it is not
necessary to reprogram every size.
6. LANCER FLOW CONTROL VALVE MODULE (LFCV) ADJUSTMENT AND MAINTENANCE
6.1
GENERAL
The water flow for the Model 600 with Flow Control Modules may be adjusted from 1.20 oz/sec
(36 ml/sec) to 2.00 oz/sec (59 ml/sec) and the syrup flow may be adjusted from .25 oz/sec
7