3

IntroDuCtIon

Your Vapor-Fire Model 200 by Lamppa Manufacturing 
and Distributing Co., Inc., is a highly-sophisticated, 
electronically-controlled,  solid  fuel  furnace  utilizing 
the latest space-age technology. If installed and op-
erated properly it should give you years of satisfying 
heat. Please read all of the instructions before install-
ing and operating your new Vapor-Fire Model 200.

We ask that you contact your sales person and ar-
range for a professional installation.

Installation must be done by a qualified installer.

LIMIteD Warranty

Your  basic  Vapor-Fire  Model  200  is  warranted  for 
twenty-five (25) years from the date of purchase by 
Lamppa Manufacturing and Distributing Co., Inc., if it 
is installed and maintained according to the instruc-
tions provided by the manufacturer.

Under this warranty the manufacturer will repair de-
fects  in  workmanship  and  replace  defective  parts 
free of charge to the customer. Any repairs that might 
require welding, burning, patching, etc., that is nor-
mally done in the manufacturer’s plant, the customer 
shall ship the furnace, freight prepaid, to the plant at 
no  cost  to  Lamppa  Manufacturing  and  Distributing 
Co., Inc.

This  warranty  does  not  apply  to  any  heat  shields, 
brick holders, or parts, such as seals, latches, hing-
es, other moving parts that wear out under normal 
usage. 

Under  this  warranty,  all  electrical  components  are 
covered for a period of 90 days from date of purchase 
if installed according to the manufacturer’s instruc-
tions. The customer shall provide to the manufactur-
er, proof of purchase. Any repairs or replacement of 
components shall have a prior agreement between 
the customer and the manufacturer, before any such 
action is undertaken.

Dimensions ...............................  24 ¼” W x 37” D x 48 ½” H
Flue Size .............................................................  6” Diameter
Heat Outlet Size .................................................  8” Diameter
Fire Door Opening ..........................................  12” w x 12” h
Draft Control .......................................................... Automatic
Draft Control Type ............................................... VF 100/200
Ash Pan Size ...................................... 10” W x 16” L x 30” H
Fire Chamber ..............................  18 ½” L x 15 ½ W x 20” H
Maximum Wood Length .................................................. 17”
Fire Chamber Lining ......................................................  Brick
grate .................................................................  ¾” Cast Iron
Fan Control ........................................... White Roger 3F05-1
Draft Requirement ........................................  .04” - .06” w.C.
Power ......................  15 Amps, 120 V, 60 Hz, #14 AWG wire

Clearance to Combustible
side .................................................................................. 12”
Front ................................................................................. 48”
From the Flue Pipe ........................................................... 18”
Clearance between the supplementary furnace and the 
central gas/oil furnace must be 6 inches.

Weight ................................................................  525 pounds
Fuel Type ..............................................................  Wood only
Chimney requirement ........................................  6” Class “A”

SPeCIFICatIonS

Figure 1

28”

24.25”

9”

24.5”

33.5”

48.5”

6”

13.5”

10”

19.75”

10”

4”

8”

Summary of Contents for Kuuma Vapor-Fire 200

Page 1: ...tion Lamppa Manufacturing Distributing Co Inc Read all instructions and rules for safe operation carefully before starting the installation Follow all state and local codes and ordinances BOX 422 TOWE...

Page 2: ...s Raking Coals Into Ash Pam Adjusting Door Latch Adjusting Door Hinges Airtight House How to Remedy Problem Typical Hot Air Hook up Disposal of Ashes Safety Considerations Creosote Formation Common Ch...

Page 3: ...nace freight prepaid to the plant at no cost to Lamppa Manufacturing and Distributing Co Inc This warranty does not apply to any heat shields brick holders or parts such as seals latches hing es other...

Page 4: ...metric draft control field 6 RC BT as described and illustrated on page 12 and 13 also see Figures 21 and 22 7 WE SUGGEST THAT A LICENSED ELEC TRICIAN BE HIRED TO DO ALL YOUR ELECTRICAL CONNECTIONS Se...

Page 5: ...el 218 753 2330 www lamppakuuma com 5 Figure 16 Figure 3 Figure 2 Fire door Front Back Primary air openings Figure 4 Grate U brick retainer Typical hot air hook up Install gasket provided Install filt...

Page 6: ...Installation and Figure 18 of Masonry Chimney note roof clearance in ac cordance with NFPA 211 COMMON CHIMNEY PROBLEMS In order to have a proper operating Solid Fuel Heat System the chimney must be ca...

Page 7: ...Restrictions The flue pipe is connected to the chimney with too many elbows reducing the draft chimney can provide 8 Multiple Venting When more than one 1 devise vents into the same chimney flue When...

Page 8: ...o that if any creosote is formed as a natural by product of combustion it will run back towards the furnace and not run through the joint to the outside of the smoke pipe The sec tion of pipe tee hold...

Page 9: ...light bind As you close the door making sure it is not too tight tighten the screws Figure 9 Figure 13 Figure 14 Door handle Door latch Adjust screw Hinge pin Hinge piece Door frame Fire door Pivot sc...

Page 10: ...ls have been raked forward the back half of the fire chamber floor should be free of any hot coals If the logs are added when there are hot coals in the back the logs will ignite and burn from the bac...

Page 11: ...perature in the fire chamber Tighten door adjustment to eliminate door leaks See sticker on the Electronic Draft Controller BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 11 WARNING L...

Page 12: ...e and clear of any ash es The long narrow slit between the two square holes MUST be kept clean see Figure 2 DISPOSAL OF ASHES Ashes should be placed in metal container with a tight fitting lid The clo...

Page 13: ...ODSHAVINGS PAPER SCRAPS DRIED CHRISTMAS TREES COAL GARBAGE TIRES OR OTHER BURNABLE PRODUCTS Important DURINGNORMALOPERATION FIRINGDOOR AND ASH DOOR MUST BE KEPT TIGHTLY CLOSED AIRLEAKAGEWILLCAUSELOSSO...

Page 14: ...ront lift off hood for more gravity heat flow For further information on using your heater safely obtain a copy of the National Fire Protection Asso ciation publication Using Coal and Wood Stoves Safe...

Page 15: ...Gas 93 300 BTU gallon Butane Gas 100 671 BTU gallon Electricity 3 413 BTU kilowatt hour WOOD BURNING FACTS BE AWARE OF CREOSOTE BUILD UP WHEN BURNING WOOD Wood burning equipment will give you trouble...

Page 16: ...hich you don t want 4 You should install another limit control switch in your bonnet at approximately the same height as to where the KUUMA duct enters the bonnet this is necessary so the control can...

Page 17: ...holes in the back of the stove so the filter box can be screwed securely to the hood MAKE SURE THE HOLES DRILLED ARE THE CORRECT SIZE SO THAT THE SCREWS WILL SECURELY HOLD THE BOX 7 Re install secure...

Page 18: ...ering the fire chamber for example as follows A At start up all three lights are on and also again at the end of the burn cycle this indi cates that the shutter is wide open B As the fire gradually in...

Page 19: ...sive leakage G Cleanout door is open H The primary opening on your KUUMA is filled with ashes I House is too air tight To correct this see Figure 15 J Wood is too wet K Avoid 90 degree elbows and hori...

Page 20: ...orm to the illustrations or descriptions Except as provided below no warranty or admission of fact expressed or implied other than as stated in LIMITED WARRANTY above is made or authorized by Dayton a...

Page 21: ...8710 0028 4 Gasket 0912 0167 0912 0167 0912 0167 0920 0069 0912 0167 0912 0167 0912 0167 5 Outlet box cover 8591 6482 8591 6482 8591 6482 8591 6482 8591 6482 8591 6482 6 Washer 8 8 8 8 8 8 8 8 8 8 7 N...

Page 22: ...BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 22...

Page 23: ...BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 23...

Page 24: ...Lamppa Manufacturing Distributing Co Inc BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 05 2012...

Reviews: