trouBLe SHootInG
iF yOu haVe trOuble starting the Fire
CHECK THE FOLLOWING:
A. Chimney draft should read between .04” to .06”
water column.
B. Smoke pipes are clean.
C. Chimney is clean.
D. More than one unit connected to one chimney.
E. Chimney may be too low. Increase its height.
F. Chimney may have cracks and excessive
leakage.
G. Cleanout door is open.
H. The primary opening on your KUUMA is filled
with ashes.
I. House is too air tight. To correct this see Figure
15.
J. Wood is too wet.
K. Avoid 90 degree elbows and horizontal piping.
L. Chimney cap must not have a mesh on it.
M. Automatic draft not 24V working – check for AL
IF BLOWER MAKES EXCESSIVE NOISE:
A. Blower fans are filled with dust.
B. Motor bearings are bad.
C. Blower is loose on its mounting bracket.