background image

GASTER N 67 ÷ 107 AW

11

EN

cod. 3541A180  -  03/2011  (Rev. 00)

4. SERVICE AND MAINTENANCE

4.1 Adjustments

All adjustment and conversion operations must be carried out by Qualified Personnel.

The manufacturer declines any liability for damage or injury caused by unqualified and
unauthorised people tampering with the unit.

Burner gas pressure adjustment

The boilers 

GASTER N 67 ÷ 107 AW

 are arranged to run on natural or liquefied gas. The

pressure setting and test are performed in the factory.

However, at first lighting, as there may be supply pressure variations, check and if nec-
essary adjust the pressure at the nozzles, respecting the values given in the technical
data table in sec. 5.3.

Pressure adjustment operations must be carried out with the boiler working, using the
pressure regulator on the 2-stage gas valves (see fig. 4)

Preliminary operations:

1.

Light the boiler and turn the control thermostat knob to minimum.

2.

Connect a pressure gauge to the pressure point on the gas manifold pipe of the
burner assembly (see part 14 of fig. 12).

3.

Remove the protection cap of the pressure regulator 4 of fig. 4.

Minimum power (1st stage) adjustment

1.

Turn the control thermostat knob slowly clockwise to the 1st click; the gas valve will
thus be supplied only on connections A and B (see fig. 4).

2.

Turn the screw 6 of fig. 4, checking that the pressure matches the values given in
the technical data table in sec. 5.3.

Maximum power (2nd stage) adjustment

1.

Turn the control thermostat knob to maximum; the gas valve will now be supplied
only on connections A, B and C (see fig. 4).

2.

Turn the screw 5 of fig. 4, checking that the pressure matches the values given in
the technical data table in sec. 5.3.

The adjustment operations must be performed uniformly on the pressure regulators of
all the valves.

B

The gas pressures measured at the burner gas manifold must be read at least
30 seconds after making the adjustments, i.e. when the flame has stabilised.

On completing the adjustment operations, turn the burner on and off 2 - 3 times with the
control thermostat and check that the pressure values are those just set; otherwise, it is
necessary to make another adjustment to bring the pressures to the correct values.

Gas conversion

The unit can work with Natural gas (G20-G25) or liquefied gas (G30-G31) and is factory-
set for use with one of the two gases, as clearly shown on the packing and dataplate.
Whenever the unit has to be used with a different gas, a conversion kit will be required,
proceeding as follows.

From natural to liquefied gas

1.

Replace the nozzles at the main burner and pilot burner, fitting the nozzles specified
in the technical data table in sec. 5.3.

2.

Remove the small cap 3 (fig. 4) from the gas valve, screw the ignition "STEP" regu-
lator 2 (contained in the conversion kit) onto the valve and refit the cap 3 on the reg-
ulator.

3.

Adjust the burner gas pressures for minimum and maximum power as described in
the previous section, setting the values given in the technical data table of section
sec. 5.3.

4.

Operations 2 and 3 must be performed on all the valves.

5.

Apply the sticker contained in the conversion kit, near the dataplate as proof of the
conversion.

From liquefied to natural gas

Carry out the same operations described above, making sure to remove the ignition
"STEP" regulator 2 of fig. 4 of the gas valve; the cap 3 of fig. 4 must be fitted directly on
the valve.

fig. 4 - Gas conversion

Key of main components

1

Pressure point upstream

2

Ignition "STEP" regulator for liquefied gas

3

Plug

4

Protection cap

5

Pressure adjustment screw for max. power

6

Pressure adjustment screw for min. power (1st stage)

7

O-ring

8

Decrease

9

Increase

V

Honeywell valve VR 4601 CB

Key of electrical connections

A + B =

Connections fed for min. power (1st stage)

A + B + C =

Connections fed for max. power (2nd stage)

4.2 Commissioning

B

Commissioning must be carried out by Qualified Personnel.

The following operations and checks must be made at first lighting, and after all mainte-
nance work involving disconnection from the systems or work on safety devices or parts
of the boiler.

Before lighting the boiler

Open any shutoff valves between the boiler and the system.

Check the tightness of the gas system, proceeding with caution and using soapy wa-
ter to check for any leaks in connections.

Fill the water system and make sure all air contained in the boiler and the system
has been vented by opening the air valve on the boiler and any vent valves in the
system.

Make sure there are no water leaks in the system or boiler.

Make sure the electrical system is properly connected.

Make sure the unit is connected to an efficient earthing system.

Make sure the pressure and gas flow values are those required for heating.

Make sure there are no flammable liquids or materials in the immediate vicinity of
the boiler.

8

9

5

4

6

V

Summary of Contents for GASTER N 67 AW

Page 1: ...ER N 67 107 AW IT ISTRUZIONE PER L USO L INSTALLAZIONE E LA MANUTENZIONE EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ES INSTRUCCIONES DE USO INSTALACI N Y MANTENIMIENTO RO INSTRUC IUNI DE UTI...

Page 2: ...uella dell eventuale ter mostato ambiente sul valore di temperatura desiderato A questo punto il bruciatore si accende e la caldaia inizia a funzionare automaticamente controllata dai suoi di spositiv...

Page 3: ...impianto La pressione di caricamento ad impianto freddo deve essere di circa 1 bar Qualora durante il fun zionamento la pressione dell impianto scendesse a causa dell evaporazione dei gas disciolti n...

Page 4: ...ull imballo e sulla targhetta dati tecnici dell apparecchio stesso Qualora si renda necessario utilizzare l apparecchio con gas di verso necessario dotarsi dell apposito kit di trasformazione e operar...

Page 5: ...ore e il corpo caldaia devono essere puliti Seguire le istruzioni al paragrafo succes sivo Gli elettrodi devono essere liberi da incrostazioni e correttamente posizionati vedi fig 9 La pressione dell...

Page 6: ...tore pilota fig 9 Bruciatore pilota 1 Porta camera combustione 2 Portellino spia 3 Bruciatore pilota 4 Elettrodo di accensione 5 Elettrodo di rilevazione 6 Ugello pilota 7 Cavo alta tensione 8 Tubetto...

Page 7: ...troppo gialle Filtro della valvola gas sporco Controllare la pressione di alimentazione del gas Ugelli gas sporchi Controllare che la caldaia non sia sporca Controllare che l aereazione del locale do...

Page 8: ...kW 67 0 77 0 87 0 97 0 107 0 P Potenza termica min riscaldamento kW 27 3 31 4 35 5 39 6 43 0 P Rendimento Pmax 80 60 C 91 4 91 5 91 4 91 5 91 5 Rendimento 30 91 3 91 4 91 2 90 5 90 5 Classe efficienz...

Page 9: ...to the required temperature value The burner will light and the boiler starts working automatically controlled by its adjustment and safety devices If the boiler is equipped with an electronic thermo...

Page 10: ...tion of gases dissolved in the water to val ues below the minimum described above the user must bring it to the initial value For correct operation of the boiler when hot its pressure must be approx 1...

Page 11: ...or use with one of the two gases as clearly shown on the packing and dataplate Whenever the unit has to be used with a different gas a conversion kit will be required proceeding as follows From natura...

Page 12: ...next section The electrodes must be free of deposits and properly positioned see fig 9 The water pressure in the system when cold must be approx 1 bar otherwise bring it to that value The expansion ta...

Page 13: ...dels GASTER AW N 97 AW and N 107 AW Pilot burner assembly fig 9 Pilot burner 1 Combustion chamber door 2 Inspection door 3 Pilot burner 4 Ignition electrode 5 Detection electrode 6 Pilot nozzle 7 High...

Page 14: ...gh too low or too yellow Gas valve filter dirty Check the gas supply pressure Gas nozzles dirty Make sure the boiler is not dirty Make sure the ventilation in the room where the unit is located is suf...

Page 15: ...0 87 0 97 0 107 0 P Min heat output in heating kW 27 3 31 4 35 5 39 6 43 0 P Efficiency Pmax 80 60 C 91 4 91 5 91 4 91 5 91 5 Efficiency 30 91 3 91 4 91 2 90 5 90 5 Efficiency class Directive 92 42 E...

Page 16: ...e enciende y la caldera comienza a funcionar autom ticamente controlada por los dispositivos de regulaci n y de seguridad Si la caldera se equipa con una centralita termost tica montada en posici n 1...

Page 17: ...cionamiento debido a la evaporaci n de los gases di sueltos en el agua por debajo del valor citado el usuario ha de restablecer el valor inicial Para un correcto funcionamiento de la caldera su presi...

Page 18: ...de datos t cnicos Para utilizarlo con otro gas es preciso montar el kit de transformaci n como se indica a continuaci n De gas natural a gas l quido 1 Quitar los inyectores del quemador principal y d...

Page 19: ...s y agua deben ser perfectamente estancas El quemador y el cuerpo de la caldera est n limpios seguir las instrucciones del p rrafo siguiente Los electrodos no presenten incrustaciones y est n bien col...

Page 20: ...y N 87 AW fig 8 Modelos GASTER AW N 97 AW y N 107 AW Grupo quemador piloto fig 9 Quemador piloto 1 Tapa de la c mara de combusti n 2 Tapa del testigo 3 Quemador piloto 4 Electrodo de encendido 5 Elect...

Page 21: ...ema mal llamas demasiado altas bajas o amarillas Filtro de la v lvula del gas sucio Controlar la presi n de alimentaci n del gas Inyectores del gas sucios Controlar que la caldera no est sucia Control...

Page 22: ...7 0 97 0 107 0 P Potencia t rmica m n en calefacci n kW 27 3 31 4 35 5 39 6 43 0 P Rendimento Pm x 80 60 C 91 4 91 5 91 4 91 5 91 5 Rendimiento 30 91 3 91 4 91 2 90 5 90 5 Clase de eficacia seg n la D...

Page 23: ...aloarea de temperatur dorit n acest moment arz torul se aprin de i centrala ncepe s func ioneze automat controlat de dispozitivele sale de re glare i de siguran n cazul n care centrala este echipat cu...

Page 24: ...unii instala iei coboar din cauza evapor rii gazelor dizolvate n ap la valori inferioare celei minime men ionate mai sus Utilizatorul va trebui s o readuc la valoarea ini ial Pentru o func ionare core...

Page 25: ...z a a cum se men ioneaz n mod clar pe ambalaj i pe pl cu a cu datele tehnice ale aparatului Dac este necesar utilizarea aparatului cu un tip de gaz diferit trebuie s achizi iona i kitul corespunz tor...

Page 26: ...ate Urma i instruc iunile din paragraful ur m tor Electrozii nu trebuie s aib incrusta ii i trebuie s fie pozi iona i corect vezi fig 9 Presiunea apei din instala ia rece trebuie s fie de aproximativ...

Page 27: ...AW i N 87 AW fig 8 Modelele GASTER AW N 97 AW i N 107 AW Grup arz tor pilot fig 9 Arz tor pilot 1 U camer de ardere 2 U i vizualizare 3 Arz tor pilot 4 Electrod de aprindere 5 Electrod de detectare 6...

Page 28: ...prea joase sau prea galbene Filtrul valvei de gaz este murdar Controla i presiunea de alimentare a gazului Duze de gaz murdare Controla i ca centrala s nu fie murdar Controla i ca nc perea n care este...

Page 29: ...45 0 49 0 Q Putere termic max nc lzire kW 67 0 77 0 87 0 97 0 107 0 P Putere termic min nc lzire kW 27 3 31 4 35 5 39 6 43 0 P Randament Pmax 80 60 C 91 4 91 5 91 4 91 5 91 5 Randament 30 91 3 91 4 9...

Page 30: ...RU cod 3541A180 03 2011 Rev 00 RU 1 2 2 1 GASTER N 67 107 AW LAMBORGHINI GASTER N 67 107 AW NOx 2 2 1 1 2 3 4 5 6 7 2 8 0 1 2 3 8 1 1 7 1 1 A 6 15 A 8 0 B 8 3 0 1 TEST 2 4 17 30 90 45 7 1 12 1 0 2 5 A...

Page 31: ...GASTER N 67 107 AW 31 RU cod 3541A180 03 2011 Rev 00 3 3 1 B 3 2 3 3 20 C B 11 B 25 Fr 1 1 5 2 3 4 B 11 B 3 5 230 50 B i sez 5 5 3 3A 2 2 A 2 B C D 40 3 A B C 40 3 A B C...

Page 32: ...GASTER N 67 107 AW sez 5 3 2 4 1 2 14 12 3 4 4 1 1 1 A B 4 2 6 4 sez 5 3 2 1 A B C 4 2 5 4 sez 5 3 B 30 2 3 G20 G25 G30 G31 1 sez 5 3 2 3 4 STEP 2 3 3 sez 5 3 4 2 3 5 STEP 2 4 3 4 4 1 2 STEP 3 4 5 6 1...

Page 33: ...N 67 107 AW 33 RU cod 3541A180 03 2011 Rev 00 8 1 1 7 1 50 C B 15 sez 4 4 8 3 0 1 TEST A cap 5 8 1 0 8 1 0 B 4 3 B 9 1 sez 5 3 GASTER N 67 107 AW 110 C 10 C 3 1 4 1 2 4 1 B 5 5 B 6 1 2 3 4 5 6 10 15...

Page 34: ...34 RU cod 3541A180 03 2011 Rev 00 A 7 N 97 AW N 107 AW 2 2 2 8 B 7 N 97 AW N 107 AW 8 C 7 GASTER AW N 67 AW N 77 AW N 87 AW 8 GASTER AW N 97 AW N 107 AW 9 1 2 3 4 5 6 7 8 10 5 5 10 1 2 3 4 5 C C B A C...

Page 35: ...15 16 9 9 2 2 2 2 50 C A B C a1 a2 a3 GASTER N 67 AW 760 100 180 1 1 4 1 1 4 3 4 GASTER N 77 AW 850 110 200 1 1 4 1 1 4 3 4 GASTER N 87 AW 930 110 200 1 1 4 1 1 4 3 4 GASTER N 97 AW 1020 110 200 1 1...

Page 36: ...5 92 42 EEC NOx 2 G20 x 6 x 2 80 7 x 2 80 8 x 2 80 9 x 2 80 10 x 2 80 G20 20 20 20 20 20 G20 13 13 13 13 13 G20 2 5 2 5 2 5 2 5 2 5 G20 3 7 76 8 91 10 07 11 22 12 38 G20 3 3 28 3 78 4 26 4 76 5 19 G3...

Page 37: ...23 modificata dalla 93 68 Direttiva Compatibilit Elettromagnetica 89 336 modificata dalla 93 68 IT EN Declaration of conformity Manufacturer declares that this unit complies with the following EU dire...

Page 38: ......

Page 39: ......

Page 40: ...GHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene pi opportuno per l evoluzione del prodotto The illustrations and data given are indicative and are no...

Reviews: