LaCie blue eye pro
Calibrating LaCie 300/500/700 Series Monitors
User Manual
page 20
5.3. Controlling the Calibration
of Your LaCie 300/500/700
Series Monitor
The
Test and Report
tool gives you the opportunity to verify the
accuracy of your monitor’s current profile settings for Gamma,
White Point, and Luminance by measuring and comparing them
to the actual monitor settings. Depending on the options that
you select, Test and Report will display a Monitor Report window
that contains:
✦
Classic: A chromaticity diagram of your monitor’s current
Gamut as well as a diagram and numerical values repre-
senting the color discrepancies measured by the tool.
✦
UDACT
1
Test & Uniformity: A certificate of conformity to
UGRA recommendations regarding soft proofing (“UGRA
certified” or “UGRA not certified”) In both cases a detailed
report can be saved for future reference. Clicking on the
Test and Report
button opens a window. Place the calibra-
tor on the target and click on the
Start
button to launch the
test process: the colorimeter measures color patches of a
series of different colors: Shades of gray, Red, Green, Blue,
Cyan, Magenta, Yellow, and Pastel values to evaluate the
quality of the calibration by comparing measured values
with expected ones.
In case you selected the UDACT test, the UGRA/FOGRA Medi-
aWedge® colors are included in the test.
1
UDACT stands for “UGRA Display Analysis and Certifi-
cation Tool”