Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 12
Gravimetric
Blender
2.7.5.2 Stock Silo Control
A regrind silo can have (optional) three sensors to detect high- low- and middle. If the
controller has these sensors, ‘Stock-Silo’ regrind control can be activated, choosing menu
(F1)
‘controller / protected parameters’
.
If the high-sensor is true, the silo is almost full. Therefore more regrind will be dispensed.
This is the same as described in ‘empty regrind control’. This will be done until the middle
sensor is not true anymore. In a defi ned number of steps the process will dispense the
original setting of the recipe.
If the low-sensor is true, the silo is almost empty. Therefore less regrind will be dispensed.
This is the inverse as described in ‘empty regrind control’. This will be done until the
middle sensor will become true. In a defi ned number of steps the process will dispense
the original setting of the recipe.
Summary of Contents for FGB-M05
Page 17: ...Rev May 2001 GraviMaster FGB M05 S Page 16 Gravimetric Blender 2 9 EQ Net Certificate...
Page 18: ...Rev May 2001 GraviMaster FGB M05 S Page 17 Gravimetric Blender 2 10 ISO Certificat...
Page 50: ...Rev May 2001 GraviMaster FGB M05 S Page 49 Gravimetric Blender 7 5 Electrical diagrams...
Page 51: ...Rev May 2001 GraviMaster FGB M05 S Page 50 Gravimetric Blender...
Page 52: ...Rev May 2001 GraviMaster FGB M05 S Page 51 Gravimetric Blender...