Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 10
Gravimetric
Blender
2.7.2.2 Method Percentage
The different component are defi ned as follows:
Regrind
:
Percentage of the batch weight
Natural
:
Percentage of the batch weight
Additive
:
Percentage of the batch weight
Total sum must be 100%.
Example
Batchweight
2000
gr.
Regrind
20.0%
Natural
1
60.0%
Natural
2
15.0%
Additive
5.0%
Regrind
: 20.0%
of
2000.0
400.0
Natural
1
: 60.0%
of
2000.0
1200.0
Natural
2
: 15.0%
of
2000.0
300.0
Additive
: 5.0%
of
2000.0
100.0
TOTAL 2000.0
2.7.3 Adding extra materials
The
defi ned amount of the component defi ned in the recipes can be changed external
using some special parameters. The controller has two methods: ‘Additive to regrind’ and
‘Regrind Control’.
IMPORTANT
Addition of extra material using ‘Additive to regrind’ and ‘Regrind Control’ is only
possible when a ‘standard’ recipe is used.
Summary of Contents for FGB-M05
Page 17: ...Rev May 2001 GraviMaster FGB M05 S Page 16 Gravimetric Blender 2 9 EQ Net Certificate...
Page 18: ...Rev May 2001 GraviMaster FGB M05 S Page 17 Gravimetric Blender 2 10 ISO Certificat...
Page 50: ...Rev May 2001 GraviMaster FGB M05 S Page 49 Gravimetric Blender 7 5 Electrical diagrams...
Page 51: ...Rev May 2001 GraviMaster FGB M05 S Page 50 Gravimetric Blender...
Page 52: ...Rev May 2001 GraviMaster FGB M05 S Page 51 Gravimetric Blender...