Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 42
Gravimetric
Blender
ALARMS
Alarm-message
Description
Action to cancel alarm
Press enter
Alarm already cancelled
Press enter
Operator must confi rm
No control voltage
No 24V control voltage present
Turn on the main-switch
or check fuses
Covers open
Security cover not present or mixerchamber
Place security-cover /
removed
mixer-chamber
Production weight
producedWeight equals produktionweight
Reset the
reached
producedWeight
No weighbin or
Zero weight of the weighbin is greater then
Loadcell must be
calibrate
‘maximumTareVariation’
calibrated or a tare
procedure must be done.
Parameters corrupted
The controller can’t read his parameters
Check the parameters
*)
correctly. All parameters will be fi lled with
standard
values.
Data corrupted
The controller can’t read the productiondata
Confi rm
*)
(production-screen). The data will be cleared.
Hopper low
The hoppersensor (optional) indicates that a
Fill hopper with material
hopper runs out of material.
Hopper empty
No material is dispensed so the controller
Fill hopper with material and
indicates that a hopper must be empty.
press the start-button.
***)
Loadcell not calibrated The controller can’t read the loadcell
Calibrate the weighbin
parameters
correctly.
Loadcell overload
Weight of the weighbin is greater than the
Remove material out of
loadcellOverload parameter.
the weigbin.
Check in recipe the
Loadcell not stable
Weightsignal from the loadcell doesn’t fi t
Press enter
*) **)
the
band.
Loadcell need
Controller needs more samples to generate a
Press enter
*)
more samples
stable weight.
Loadcell boundary error To much weight-samples doesn’t fi t the band. Press enter
*)
Silo high
Silo supply hopper is full for several batches. Counter will
(High sensor is activated)
automaticaly cleared.
Regrind process par
Given hoppernumbers doesn’t contain regrind Check the regrind
confl ict
or percentage
control parameters
Additive regrind par
Given hoppernumber doesn’t contain additive Check the
confl ict
AdditiveToRegind
parameters
Summary of Contents for FGB-M05
Page 17: ...Rev May 2001 GraviMaster FGB M05 S Page 16 Gravimetric Blender 2 9 EQ Net Certificate...
Page 18: ...Rev May 2001 GraviMaster FGB M05 S Page 17 Gravimetric Blender 2 10 ISO Certificat...
Page 50: ...Rev May 2001 GraviMaster FGB M05 S Page 49 Gravimetric Blender 7 5 Electrical diagrams...
Page 51: ...Rev May 2001 GraviMaster FGB M05 S Page 50 Gravimetric Blender...
Page 52: ...Rev May 2001 GraviMaster FGB M05 S Page 51 Gravimetric Blender...