74
Catalog #
Kit
Description
Max. Flow
Rate
Max. Working
Pressure
9828000
†††
Hot (HW) and Cold Water (CW)
Mixing Gooseneck
For Hoods with Interior
Depths of 24” to 37.7”
3.5 GPM
(13.2 LPM)
40 psi
Deionized/Distilled Water Gooseneck Fixture Kit
For mounting on the left or right side of any filtered hood. Each kit
includes one remotely-controlled, gray PVC rigid gooseneck with
stainless steel valve and ¼-inch O.D. tubing and white fixture knob.
Inlet tubing is not included.
Shipping weight 10 lbs. (5 kg)
Catalog #
Kit
Description
Max. Flow
Rate
Max. Working
Pressure
9853400
†††
Deionized/Distilled Water (DW)
Gooseneck
For Hoods with Interior
Depths less than
37.7”
3.5 GPM
(13.2 LPM)
40 psi
GPM = gallons per minute, LPM = liters per minute, CFM = cubic feet per minute, BTU/sec = British thermal unit per second, LBM/min = pounds mass per
minute,
*Contact Labconco for ordering information on Standard Service Features with chrome-plated bras hose connectors for protector Stainless Steel Hoods,
†Maximum allowable pressure is 200 psi with a working pressure of 40 psi, ** Protector Stainless Steel and PVC Hoods require drill hole in liner,
†† WaterSaver is registered trademark of WaterSaver Company., ††† Requires 1.375” dia. drill hole in liner.
Installing an Electrical Duplex Outlet
Your filtered hood can be ordered with duplex outlets, however, if you ordered a model
without an electrical duplex outlet you can have one installed in the field by a qualified
electrician.
Electrical Receptacle Kits
For mounting in left or right side of any 3 FT, 4 FT, 5 FT, 6 FT or 8 FT filtered hood.
Each Receptacle Kit includes and electrical receptacle, wiring, junction box and
receptacle cover plate. The international GFCI Switch is mountable in one corner post
location above or below any international single outlet.
Catalog #
Kits
Outlet Type
Shipping Wt.
lbs
kg
9851100
115 volts, 20 amps AC, 60 Hz
Duplex, U.S.
4
2
9851500
115 volts, 20 amps AC, GFCI 60 Hz
Duplex, U.S.
4
2
9854200
230 volts, 20 amps AC, 60 Hz
Duplex, U.S.
4
2
9412500
230 volts, 13 amps AC, 50 Hz
Single, British (UK)
4
2
9412700
230 volts, 16 amps AC, 50 Hz
Single, Schuko
4
2
9412900
230 volts, 10 amps AC, 50 Hz
Single, China
4
2
9413100
230 volts, 10 amps AC, 50 Hz
Single, Australia
4
2
9413900
230 volts, 6-16 amps AC, 50 Hz
Single, India-South Africa
4
2
9414100
International GFCI Switch, 16 amps
Not Applicable
4
2
Table 9-10
Table 9-9
Table 9-8
Figure 9-5
Summary of Contents for Protector Echo
Page 78: ...78 Fans and Lights not working...
Page 79: ...79 Vertical sash no longer operates smoothly...
Page 80: ...80 Electrical duplex outlets no longer have power Fan operates but lights dim or not working...
Page 81: ...81 Contaminates outside the filtered hood...
Page 82: ...82 Lights operate but fans will not...
Page 83: ...83 Smart Command Alarms...
Page 84: ...84 If needed contact Labconco to troubleshoot further...
Page 94: ...94 Wiring Diagram Figure C 1...