INSTRUCTION MANUAL FOR THE INSTALLER
96
LSI 001 -EN- REV. 06
6.3
EK MODEL
This model is equipped with an electronic control board which controls the water level in the
boiler, and the activation of the motor pump and of the cup warmer heating element (optional). It
also controls possible malfunctions to be viewed on touchpad symbols.
OpERATING TEMpERATURE ADJUSTMENT FOR THE ELECTRIC HEATING SYSTEM
The electric heating system of the appliance is already set by the manufacturer to operate at a temperature
of
120 °C in the boiler, corresponding to 1 bar boiler pressure. Boiler pressure is viewed on the pressure
gauge (4) situated on the front panel of the appliance.
In order to increase or decrease the boiler pressure,
it is necessary to operate on the electric pressure
switch (Pict 21) which is inside the machine (on the
right side), as indicated here below:
• Turn the adjustment screw anti-clockwise to
increase boiler pressure.
• Turn the adjustment screw clockwise to decrease
it.
Boiler pressure (at operating temperature) is normally modified exclusively in order to adapt the machine
temperature to the particular type of coffee blend so as to obtain the best result in the cup.
ELECTRIC CUp WARMER (optional)
In the models equipped with the electric cup warmer, to activate it, move the main switch button (3) from
position
1 (standard operation of the machine) to position 2. To deactivate it, move it back to position 1.
6.4 ALARM MANAGER – EK MODEL
This model communicates any anomalies through the relevant symbols on the touchpads.
1. SYMBOL CORRESPONDING TO THE COFFEE DOSE BUTTON ON DELIVERY MODE, FLASHING AFTER
5-6 SECONDS:
• Coffee ground too finely.
• Missing reading of the pulses sent by the flow meter to the dispensing group.
2. ALL DOSE SYMBOLS ON ALL TOUCHPADS FLASHING AND TEMPERATURE SYMBOLS
SWITCHED OFF:
• The automatic refill system for the boiler has been operating for longer than
3 minutes (total block of
all machine operations). To restore normal operation, switch the machine off using the main switch.
If the problem occurs again, check the automatic refill system for the boiler.
WARNING!
Cut off power while operating on the pres-
sure switch.
20
00
8
ADJUSTMENT SCREW
PRESSURE SWITCH