Power Connection
3-3
3.3
Power Connection
The Series 5000 requires AC power to operate. The power source requirements are
115 VAC, 50–60 Hz, single phase or 220 VAC, 50 Hz. The system is designed to
protect against over and under voltage and transient spikes. However, it is always
best to check the power source carefully before operating the equipment. Ensure
that the power source is within the required operational tolerances, with minimal
noise and voltage spikes. As the quality of onboard AC power varies from vessel
to vessel, it is best to actually check the AC power source with a voltmeter or an
oscilloscope.
3.3.1 Connecting Cables and Power Cords
The hardware must be fully interconnected for real time data collection. The
computer may be used standalone when desired for display of stored data. Connect
the cables as described below to set up the system for normal operation.
Tow cable.
Refer to “Towfish Setup” on page 3-5 for instructions on
connecting the tow cable.
NMEA navigation data line.
Connect the data line from your NMEA
navigation equipment to the TPU COM2 connector.
LAN cables.
One end of a LAN cable connects to the LAN connector on the
rear panel of the TPU, and the other end connects to the Ethernet Hub. A
second LAN cable connects from the Ethernet Hub to the computer.
Computer cables.
Connect the computer display, keyboard and mouse cables
to the computer.
Power Cords.
Connect the power cords to the Ethernet Hub, the TPU, the
display, and the computer.
Confirm that the TPU and the computer are set to the local voltage (115 VAC or
220 VAC) and that the proper transformer (115 or 220 VAC to 12 VDC) is used
for the Ethernet Hub).
Since a variety of power connectors are in use throughout the world, it may be
necessary to use an adapter or to cut off the US-type plug and re-terminate it with a
new plug. In the event that the power cord for the TPU must be re-terminated, the
wires should be connected in accordance with Table 3-1.
CAUTION
Application of improper AC power may damage the Series
5000 Sonar System. Do not turn the equipment on until you have checked
the supply voltage and frequency.
Summary of Contents for SERIES 5000
Page 27: ......
Page 59: ......
Page 162: ...Splashproof TPU Drawings 6 13 ...
Page 164: ...Splashproof TPU Drawings 6 15 ...
Page 166: ...Splashproof TPU Drawings 6 17 ...
Page 167: ......
Page 170: ...A 3 Figure A 1 Cable Length vs Towfish Depth Graph 1 ...
Page 172: ...A 5 Figure A 3 Cable Length vs Towfish Depth Graph 3 ...
Page 174: ...A 7 Figure A 5 Cable Length vs Towfish Depth Graph 5 ...
Page 175: ......
Page 179: ......
Page 203: ......
Page 262: ...NMEA 0183 Formats and Information D 59 D 13 NMEA 0183 Formats and Information ...
Page 264: ...NMEA 0183 Formats and Information D 61 ...
Page 265: ......
Page 268: ...E 3 ...
Page 270: ...E 5 ...
Page 272: ...E 7 ...
Page 274: ...E 9 ...
Page 276: ...E 11 ...
Page 278: ...E 13 ...
Page 280: ...E 15 ...
Page 282: ...E 17 ...
Page 283: ......